Advertisement

Quick Links

This manual only describes the specifications for FX
For complete operation, wiring, mounting and programming instructions please refer to the FX
-20GM HARDWARE PROGRAMMING MANUAL, FX PROGRAMMING MANUAL ΙΙ and FX SERIES
FX
2N
HARDWARE MANUAL.
These manuals should be read and understood before attempting to install or use the unit.
1. Reference manual
Refer to the under mentioned manual for details about product installation, and programming.
1) FX
-10GM, FX
2N
2N
The installation of FX
2) E-20TP-E OPERATION MANUAL
The operation of the input of the program which uses E-20TP-E and the monitor and the test is
explained.
3) FX-PCS-VPS/WIN-E SOFTWARE MANUAL
The operation program is input using the FX-PCS-VPS/WIN-E software. This manual explains the
operation of the monitor and test functions.
4) FX-PCS-KIT-GM-EE SOFTWARE MANUAL
The program is input via the FX-PCS-KIT-GM-EE. The manual explains the operation of the monitor
and test functions.
The manual in 1) is not included with the product. Please request from the shop where the units was pur-
chased if required.
The manuals in 2), 3) and 4) are included with the product.
2. Outline of the unit
The FX
-10GM positioning controller (hereinafter call FX
2N
that enables the positioning control of a stepping motor or a servo motor via the drive unit.
One FX
-10GM can control 1 axis.
2N
Both dedicated positioning language (cod instructions) and sequence language (basic instructions
and application instructions) are available.
A pulse generator can be connection.(The manual pulse generators must be an open collector output
type.)
The zero return operation at each start can be omitted with a servo amplifier with the absolute position
(ABS) detection function.
The FX
-10GM can be used alone.
2N
When an FX
-10GM is connected with an FX
2N
troller (here after call PLC), the positioning data can be read/written.
When connecting to an FX
When connecting to an FX
3. External dimensions
87(3.43)
74(2.91)
-20GM HARDWARE PROGRAMMING MANUAL
-10GM and FX
2N
2N
PLC, the FX
2NC
PLC, the FX
3UC
60(2.36)
13(0.51)
POWER
READY
AUTO
ERROR
CPU-E
MANU
Power supply
cable
FX
USER'S GUIDE
-10GM positioning controller.
2N
-20GM and wiring and the instructions are explained.
-10GM or 10GM) is a pulse chain output unit
2N
/FX
/FX
2N
2NC
3U
-CNV-IF must be used.
2NC
-CNV-IF or FX
2NC
3UC
FX -10GM
2N
START
STOP
ZRN
SVRDY
FWD
SVEND
RVS
PGO
DOG
FP
LSF
RP
LSR
CLR
X0
X1
X2
X3
Y0
Y1
Y2
Y3
Y4
Y5
-10GM
2N
JY992D77701D
/FX
series Programmable logic con-
3UC
-1PS-5V must be used.
Din rail width: 35mm
Weight: approx.0.3kg
Dimensions mm(inch)
-10GM,
2N

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the JY992D77701D and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Mitsubishi JY992D77701D

  • Page 1 -10GM USER’S GUIDE JY992D77701D This manual only describes the specifications for FX -10GM positioning controller. For complete operation, wiring, mounting and programming instructions please refer to the FX -10GM, -20GM HARDWARE PROGRAMMING MANUAL, FX PROGRAMMING MANUAL ΙΙ and FX SERIES HARDWARE MANUAL.
  • Page 2: Product Composition

    4. Product composition 4.1 Each part name The name and description of each part of the FX -10GM are explained below. ➀ Operation indicator LED ➀ ➁ ➂ ➃ ➁ MANU/AUTO switch ➂ POWER Connector for programming tool ➄ READY AUTO ERROR FX -10GM...
  • Page 3: Connection With Plc

    4.5 Connection with PLC Refer to the FX -10GM, FX -20GM HARDWARE PROGRAMMING MANUAL for details concerning the system configuration. -CNV-IF -10GM Main unit -16EX GM-5EC (I/O Extension of main unit of the PLC) The FX -GM-5EC cable is used to connect the FX -10GM to the PLC.
  • Page 4: Power Supply Specification

    5. Specification 5.1 Power supply specification Item Contents Power supply DC24V +10%, -15% Allowance power The operation is continued to the momentary power failure is 5ms or less. failure time Power consumption Fuse 125V 1A 5.2 General specifications Item Contents 0 to 55 °C (operation).
  • Page 5: Input Specifications

    Item Contents Program method: The program is written in the FX -10GM by a special programming tool, and the positioning control is done. Control method Table method : When the PLC is used together, the positioning control is done by the FROM/TO instruction. Program No.
  • Page 6: Output Specification

    All examples and diagrams shown in this manual are intended only as an aid to understand- ing the text, not to guarantee operation. Mitsubishi Electric will accept no responsibility for actual use of the product based on these illustrative examples.
  • Page 7 FX -10GM CPU-E START STOP SVRDY ➃ MANU SVEND I/O display JY992D77701D ➄ Connector for PLC extension block -16EX GM-5EC ➅ Hook for DIN rail installation (I/O Extension of main This manual only describes the specifications for FX -10GM positioning controller.
  • Page 8 All examples and diagrams shown in this manual are intended only as an aid to understand- Group 2 Approx. 0.5msec Approx.16µs ing the text, not to guarantee operation. Mitsubishi Electric will accept no responsibility for Response Command units: mm, deg, inch, pls, (relativity/absolutely)

This manual is also suitable for:

Melsec-f fx2n-10gm

Table of Contents