FX2N-32DP-IF Profibus-DP Interface Unit
Table C-62: FX
Nr.
Parameter Name
14
maximum speed
(15th)
upper word
15
bias speed
(16th)
16
Jog speed lower
(17th)
word
17
Jog speed upper
(18th)
word
18
zero ret. hi. speed
(19th)
lower word
19
zero ret. hi. speed
(20th)
upper word
-10PG (Motorola Format)
2N
Value Setting List
Default: 7 (0007 Hex)
Default: 0 (0000 Hex)
Default: 10000 (2710 Hex)
Default: 0 (0000 Hex)
Default: 41248 (A120 Hex)
Default: 7 (0007 Hex)
Description
Set upper word of maximum speed.
(BFM #1)
Setting range (BFM #1, #0):
-2,147,483,648 to 2,147,483,467
(00000000 to FFFFFFFF Hex)
The range of pulse-converted value
is 1 to 1,000,000 Hz (000000001 to
000F4240 Hex)
Set bias speed. (BFM #2)
Setting range:
0 to 32767 (0000 to 7FFF Hex)
The range of pulse-converted value
is 0 to 30000 Hz (0000 to 7530
Hex)
Set lower word of JOG speed.
(BFM #3)
Setting range (BFM #4, #3):
-2,147,483,648 to 2,147,483,467
(00000000 to FFFFFFFF Hex)
The range of pulse-converted value
is 1 to 1,000,000 Hz (000000001 to
000F4240 Hex)
Set lower word of JOG speed.
(BFM #4)
Setting range (BFM #4, #3):
-2,147,483,648 to 2,147,483,467
(00000000 to FFFFFFFF Hex)
The range of pulse-converted value
is 1 to 1,000,000 Hz (000000001 to
000F4240 Hex)
Set lower word of the home position
return speed. (BFM #5)
Setting range (BFM #6, #5):
1 to 2,147,483,467 (00000001 to
7FFFFFFF Hex)
The range of pulse-converted value
is 1 to 1,000,000 Hz (000000001 to
000F4240 Hex)
Set upper word of the home
position return speed. (BFM #6)
Setting range (BFM #6, #5):
1 to 2,147,483,467 (00000001 to
7FFFFFFF Hex)
The range of pulse-converted value
is 1 to 1,000,000 Hz (000000001 to
000F4240 Hex)