4
Parts Replacement and Cleaning Procedure > Motors > Removing the Gripper Motor (M7)
Removing the Gripper Motor (M7)
1) Remove the lower
2) Pull out the tray auxiliary guide until it stops.
processing tray unit.
(Refer to page 4-15)
3) Remove the 3 screws and the belt, and disconnect the 2 connectors, and then remove the
gripper motor along with the support plate.
x3
x2
4
Parts Replacement and Cleaning Procedure > Motors > Removing the Gripper Motor (M7)
F-4-41
4) Remove the 2 screws, and then remove the gripper motor.
x2
F-4-42
F-4-43
4-20