Trk Board - Samsung OFFICESERV 7100 Service Manual

Hide thumbs Also See for OFFICESERV 7100:
Table of Contents

Advertisement

CHAPTER 13. Error! Use the Home tab to apply 제목 1,장 제목 1 to the text that you want to appear here.

3.4.5 8TRK Board

The procedure for resolving the problem that occurs on 8TRK board is as follows:
3.4.5.1 8TRK Board is not Detected
The procedure for resolving the problem that occurs when 8TRK is not detected is as follows:
Check if a group from slot 1~2
groups does not operate.
Does a group not operate?
No
Are all slots abnormal?
No
Does a problem
occurs when the corresponding
8TRK board is mounted?
No
Repair the slot connector.
3-26
Yes
Replace the MP10/11 board.
Yes
- Check with normal board again.
- Repair MP10/11 board.
Yes
Check the signals of DATA BUS and
CARD ENABLE of board.
© SAMSUNG Electronics Co., Ltd.