Samsung OFFICESERV 7100 Service Manual page 181

Hide thumbs Also See for OFFICESERV 7100:
Table of Contents

Advertisement

1) x: Slot number
When mounting on the slot 1: 0
When mounting on the slot 4: 3
When mounting on the slot 5: 4
Result display
PASS: FALC inside the corresponding TEPRI board operates normally.
FAIL: FALC inside the corresponding TEPRI board operates abnormally.
VERS
Test item: This displays the version and the date of issue of the offline program.
Result display
V100: 20031220: This indicates that the version is V100 and the date of issue is
2003.12.20.
MMEMx
Test item: This checks the memory inside the MGI board. It should be tested only after
checking if the MGI CARD operates normally. When executing this command, the
MGI board to be tested should be mounted on the one-stage cabinet before testing.
'x' is the slot number.
Slot number: 0~4
When mounting on the slot: 0
Result display
PASS: The memory status of the corresponding MGI board is normal.
FAIL: The memory status of the corresponding MGI board is abnormal.
MGIDx
Test item: This checks if the board ID of the MGI board can be read normally.
Namely, this checks if the type of the MGI board of the designated slot corresponds to
the ID which has been read actually. When executing this command, the MGI board to
be tested should be mounted on the one-stage cabinet before testing. 'x' is the slot
number.
Slot number: 0~4
When mounting on the slot 1: 0
Result display
PASS: The ID which has been read from the corresponding MGI board corresponds
to the type of the designated board.
FAIL: The ID which has been read from the corresponding MGI board does not
correspond to the type of the designated board.
© SAMSUNG Electronics Co., Ltd.
OfficeServ 7100 Service Manual
4-25