CHAPTER 13. Error! Use the Home tab to apply 제목 1,장 제목 1 to the text that you want to appear here.
3.4.6.3 LED for Indicating Line is Abnormal
The procedure for resolving the problem that occurs when the LED for indicating line of
TEPRI2 board is as follows:
Start
LOS LED is ON?
No
SYN LED is ON?
No
AIS LED is ON?
No
End
3-32
Yes
Check signals between PIN 2/3 of
U6,7(FALC56). If signal is not
detected, track and repair signal.
Yes
Turn off CRC from PRI option.
SYN LED is ON?
No
End
- Select clock source through
MMC 826, the program for
selecting it based on system
Yes
clock synchronization
- Check signal distortion after
identifying signals between PIN
2/3 of U6,7(FALC 56)
- Select clock source through
MMC 826, the program for
Yes
selecting it based on system
clock synchronization
- Check signal distortion after
identifying signals between PIN
2/3 of U6,7(FALC56)