Alcatel-Lucent 7750 Reference Manual page 171

Service router radius attributes
Table of Contents

Advertisement

Table 53: Enhanced Subscriber Management Accounting (limits) (Continued)
Attribute ID
Attribute Name
44
Acct-Session-Id
45
Acct-Authentic
46
Acct-Session-Time
47
Acct-Input-Packets
48
Acct-Output-Packets
49
Acct-Terminate-Cause
50
Acct-Multi-Session-Id
52
Acct-Input-Gigawords
53
Acct-Output-
Gigawords
7750 SR RADIUS Attributes Reference Guide
Type
Limits
string
22 bytes
(number
format) max.
253 bytes
(description
format)
29 bytes
(DSM format)
integer
4
integer
4 Bytes
4294967295
seconds
integer
32 bit counter
4294967295
packets
integer
32 bit counter
4294967295
packets
integer
4 Bytes
string
22 bytes
(number
format) max.
253 bytes
(description
format)
29 bytes
(DSM format)
integer
32 bit counter
integer
32 bit counter
RADIUS Attributes Reference
SR OS Format
Internal generated 22 byte string (number
format): Acct-Session-Id =
241AFF0000003250B5F750
DSM: Acct-Session-Id = 01-02-00-00-00-19-
00-00-00-01
# value = 2 (local) for local user database
authentication 1=Radius, 2=Local
For Example: AUTHENTIC [45] 4 Radius(1)
For example: Acct-Session-Time = 870
For example: Acct-Input-Packets = 15200
For example: Acct-Output-Packets = 153537
Supported causes: 1=User-Request, 2=Lost-
Carrier, 3=Lost-Service, 4=Idle-Timeout,
5=Session-Timeout, 6=Admin-Reset, 8=Port-
Error, 10=NAS-Request, 15=Service-
Unavailable See also table Acct Terminate
Cause for complete overview
For example: Acct-Terminate-Cause = User-
Request
Internal generated 22 byte string (number
format): Acct-Multi-Session-Id =
241AFF0000003250B5F750
DSM: Acct-Multi-Session-Id = 01-02-00-00-
00-19-00-00-5b-d9
For example: Acct-Input-Gigawords = 1
For example: Acct-Output-Gigawords = 3
Page 171

Advertisement

Table of Contents
loading

Table of Contents