Digital Input Functions
Digital inputs
Value:
No function
Reset
Coasting stop, inverse
Reset and coasting stop, inverse
Quick-stop, inverse
DC-braking, inverse
Stop inverse
Start
Latched start
Reversing
Start reversing
Only start clockwise, on
Only start anti-clockwise, on
Jog
Preset reference, on
Preset reference, lsb
Preset reference, msb
Freeze reference
Freeze output
Speed up
Speed down
Choice of Setup, lsb
Choice of Setup, msb
Choice of Setup, msb/speed up
Choice of Setup, lsb/speed down
Catch-up
Slow-down
Ramp 2
Mains failure inverted
Pulse reference
Function:
Description of choice:
No function The frequency converter does not react
to signals transmitted to the terminal.
Reset Resetting the frequency converter after a
TRIP/ALARM; however not all alarms can be reset.
Coasting stop (terminal 27) Inverted input (NC).
The frequency converter leaves the motor in free
mode. Logic '0' => coasting stop.
Reset and coasting stop (terminal 27) Inverted
input (NC). The frequency converter leaves the
= factory setting. () = display text [] = value for use in communication via serial communication port
MG.55.A6.02 - VLT is a registered Danfoss trademark
Terminal no.
parameter
(NO OPERATION)
(RESET)
(COAST INVERSE)
(COAST & RESET INVERS)
(QSTOP INVERSE)
(DCBRAKE INVERSE)
(STOP INVERSE)
(START)
(LATCHED START)
(REVERSING)
(START REVERSE)
(ENABLE START FWD.)
(ENABLE START REV)
(JOGGING)
(PRESET REF. ON)
(PRESET REF. SEL. LSB)
(PRESET REF. MSB)
(FREEZE REFERENCE)
(FREEZE OUTPUT)
(SPEED UP)
(SPEED DOWN)
(SETUP SELECT LSB)
(SETUP SELECT MSB)
(SETUP MSB/SPEED UP)
(SETUP LSB/SPEED DOWN)
(CATCH UP)
(SLOW DOWN)
(RAMP 2)
(MAINS FAILURE INVERSE)
(PULSE REFERENCE)
motor in free mode and successive resets the drive.
Logic '0' => coasting stop and reset.
Quick-stop inverted (terminal 27) Inverted input
(NC). Generates stop in accordance with the quick-stop
ramp time (Parameter 212). When the motor is stopped
the shaft is then in free mode. Logic '0' => Quick-stop.
DC braking inverted (terminal 27) Inverted input
(NC). Stopping the motor by energizing it with a DC for
a certain time. See parameter 125-127. The function
is only active when the value in parameter 126 is
different from 0. . Logic '0' => DC braking.
®
VLT
5000 FLUX
16
17
18
19
27
300 301 302 303 304 305 306 307
(Operating Command Group)
[0]
[0]
[0]
[0]
[1]*
[1]
[0]*
[1]
[2]
[3]
[2]
[2]
[4]
[1]*
[2]
[1]*
[2]
[3]
[3]
[3]
[3]
[4]
[4]
[5]
[5]
[6]
[6]
[7]
[7]*
[8]
[8]
[9]
[9]
[10]
[10]
[11]
[11]
[12] [12]
[13] [13]
29
32
33
[0]
[0]
[0]
[1]
[1]
[1]
[2]
[2]
[2]
[3]
[3]
[4]
[3]
[5]*
[4]
[4]
[6]
[5]
[5]
[7]
[6]
[8]
[6]
[9]
[7]
[7]
[10]
[8]
[8]
[11]
[9]
[12]
[9]
[13]
[10]
[14]
[10]
[11]*
[11]*
[15]
[12]
[16]
[12]
[17]
[13] [13]
[18]
[14] [14]
[28]
89
Need help?
Do you have a question about the VLT 5000 FLUX and is the answer not in the manual?
Questions and answers