YASKAWA D1000 Series Instruction Manual page 192

Type cimr-du/power regenerative converter 200 v class, three-phase input: 5 to 130 kw/400 v class, three-phase input: 5 to 630 kw
Hide thumbs Also See for D1000 Series:
Table of Contents

Advertisement

B.2 Parameter Tables
No.
(Addr.
Name
Hex)
U2-28
Malfunctioned
(7FCH)
Module
DC Bus Voltage
U2-51
Reference at
(840H)
Previous Fault
(Before SFS)
DC Bus Voltage
U2-52
Feedback at
(841H)
Previous Fault
U2-53
DC Side Current
(842H)
at Previous Fault
Power Supply
U2-54
Voltage at
(843H)
Previous Fault
Power Supply
U2-55
Side Current at
(844H)
Previous Fault
U2-56
DC Side Power at
(845H)
Previous Fault
Power Supply
U2-57
Side Power at
(846H)
Previous Fault
Power Supply
U2-58
Frequency at
(847H)
Previous Fault
Power Supply
U2-59
Side Current
(848H)
Reference at
Previous Fault
U2-60
Power Factor at
(849H)
Previous Fault
Active Current
U2-61
Reference at
(84AH)
Previous Fault
Reactive Current
U2-62
Reference at
(84BH)
Previous Fault
DC Bus Voltage
U2-63
Reference at
(84CH)
Previous Fault
(After SFS)
Avr Input
U2-64
(Voltage
(84DH)
Deviation) at
Previous Fault
Control Voltage
U2-65
Reference (Vq) at
(84EH)
Previous Fault
Control Voltage
U2-66
Reference (Vd) at
(84FH)
Previous Fault
192
LCD
Display
Displays the module where the previous fault occurred as a decimal
Fault Axis
number.
Note: This parameter is only available in 4A0630.
DC V
Shows the DC Bus Voltage Reference.
Command
DC V
Shows the DC bus voltage feedback value.
Feedback
DC Current Shows the estimated current on the bus on the DC side.
AC Voltage Shows the power supply voltage.
AC Current Shows the current on the power supply side.
DC Power
Shows the power on the DC side.
AC Power
Shows the power on the power supply side.
AC
Shows the frequency on the power supply side.
Frequency
AC Current
Shows the current reference on the power supply side when the most
Ref
recent fault occurred.
Power
Shows the power factor when the most recent fault occurred.
Factor
Active
Shows the active current when the most recent fault occurred.
Current
Reactive
Shows the reactive current when the most recent fault occurred.
Current
DC V SFS
Shows the DC bus voltage reference after the soft starter.
Level
AVR Input Shows the Avr input.
Voltage Ref
Shows the control voltage reference (Vq) when the most recent fault
(Vq)
occurred.
Voltage Ref
Shows the control voltage reference (Vd) when the most recent fault
(Vd)
occurred.
YASKAWA ELECTRIC TOEP C710656 07A YASKAWA Power Regenerative Converter - D1000 Instruction Manual
Description
Analog
Output
Unit
Level
No signal
output
available
No signal
output
1 V
available
No signal
output
1 V
available
No signal
output
1 A
available
No signal
output
1 V
available
No signal
output
1 A
available
No signal
output
1 kW
available
No signal
output
1 kW
available
No signal
output
0.1 Hz
available
No signal
output
1 A
available
No signal
output
1%
available
No signal
output
0.1%
available
No signal
output
0.1%
available
No signal
output
1 V
available
No signal
output
1 V
available
No signal
output
1 V
available
No signal
output
1 V
available

Advertisement