5.2 Fault Detection
Digital Operator
Display
Control Board
CPF03
Connection Error
Cause
There is a connection error
Converter fails to operate properly due to noise
interference
Digital Operator
Display
EEPROM Memory
CPF06
Cause
There is an error in EEPROM control circuit
The power supply was switched off while
parameters were being saved to the converter
Digital Operator
Display
CPF07
Terminal Board
Connection Error
CPF08
Cause
There is a faulty connection between the
terminal board and the control board
Digital Operator
Display
Control Board
CPF23
Connection Error
Cause
Hardware is damaged
Digital Operator
Display
CPF24
Converter Signal Fault
Cause
Hardware is damaged
Digital Operator
Display
MECHATROLINK-II
E5
Watchdog Timer Error
Cause
Data has not been received from the PLC
108
Fault Name
Connection error between the control board and the converter
Turn off the power and check the connection between the control board and the converter.
• If the problem continues, replace the control board or the entire converter. Contact Yaskawa or
a Yaskawa representative for instructions on replacing the control board.
Check the various options available to minimize the effects of noise.
• Counteract noise in the control circuit, main circuit, and ground wiring.
• Use only recommended cables or other shielded line. Ground the shield on the controller side
or the converter input power side.
• Ensure that other equipment such as switches or relays do not cause noise. Use surge
suppressors if required.
• Separate all communication wiring from converter power lines. Install an EMC noise filter to
the converter power supply input.
Fault Name
Error in the data saved to EEPROM
Data Error
Turn off the power and check the connection between the control board and the converter.
• If the problem continues, replace the control board or the entire converter. Contact Yaskawa or
a Yaskawa representative for instructions on replacing the control board.
Reinitialize the converter (A1-03 = 2220, 3330).
Fault Name
There is a faulty connection in the removable terminal block.
• Turn off the power and reconnect the terminal board.
• If the problem continues, replace the control board or the entire converter. Contact Yaskawa or
a Yaskawa representative for instructions on replacing the control board.
Fault Name
Connection error between the control board and the converter
Turn off the power and check the connection between the control board and the converter.
• If the problem continues, replace the control board or the entire converter. Contact Yaskawa or
a Yaskawa representative for instructions on replacing the control board.
Fault Name
The converter capacity cannot be detected correctly (converter capacity is checked when the
converter is powered up).
If the problem continues, replace the control board or the entire converter. Contact Yaskawa or a
Yaskawa representative for instructions on replacing the control board.
Fault Name
The watchdog timed out.
Execute DISCONNECT or ALM_CLR, then issue a CONNECT command or SYNC_SET
command and proceed to phase 3. Refer to the SI-T3 Option Technical Manual for more details
on troubleshooting.
YASKAWA ELECTRIC TOEP C710656 07A YASKAWA Power Regenerative Converter - D1000 Instruction Manual
Details
Possible Solution
Details
Possible Solution
Details
Possible Solution
Details
Possible Solution
Details
Possible Solution
Details
Possible Solution

Advertisement

Table of Contents
loading

Table of Contents