◆ U: Monitors

Monitor parameters allow the user to view converter status, fault information, and other data concerning converter
operation.
No.
(Addr.
Name
Hex)
U1-10
Input Terminal
(49H)
Status
U1-11
Output Terminal
(4AH)
Status
U1-12
Drive Status
(4BH)
U1-13
Terminal A1 Input
(4EH)
Level
U1-14
Terminal A2 Input
(4FH)
Level
U1-15
Terminal A3 Input
(50H)
Level
U1-18
oPE Fault
(61H)
Parameter
YASKAWA ELECTRIC TOEP C710656 07A YASKAWA Power Regenerative Converter - D1000 Instruction Manual
LCD
Display
U1: Operation Status Monitors
Displays the input terminal status.
U1 - 10=
Input Term
Sts
Displays the output terminal status.
U1 - 11=
Output
Term Sts
Verifies the converter operation status.
U1 - 12=
0 0 0 0 0 0 0 0
Int Ctl Sts 1
Term A1
Displays the signal level to analog input terminal A1.
Level
Term A2
Displays the signal level to analog input terminal A2.
Level
Term A3
Displays the signal level to analog input terminal A3.
Level
OPE Error
Displays the parameter number that caused the oPE02 or oPE08 operation
Code
error.
Description
0 0 0 0 0 0 0 0
1: ON
0: OFF
Digital input 1
(terminal S1 enabled)
Digital input 2
(terminal S2 enabled)
Digital input 3
(terminal S3 enabled)
Digital input 4
(terminal S4 enabled)
Digital input 5
(terminal S5 enabled)
Digital input 6
(terminal S6 enabled)
Digital input 7
(terminal S7 enabled)
Digital input 8
(terminal S8 enabled)
0 0 0 0 0 0 0 0
1: ON
0: OFF
Multi-Function Relay Output
(terminal M1-M2)
Multi-Function Relay Output
(terminal M3-M4)
Multi-Function Relay Output
(terminal M5-M6)
Reserved
Fault Relay
(terminal MA/MB-MC closed
MA/MB-MC open)
Bit 0: AUv reset. (0: Not completed, 1: Reset)
Bit 1: PF3 reset (0: Not completed, 1: Reset)
Bit 2: Rated frequency detection
(0: Not completed, 1: Completed)
Bit 3: Phase order detection
(0: Not completed, 1: Completed)
Bit 4: Power supply established
(0: Not completed, 1: Completed)
Bit 5: Fdv detection (0: Not detected, 1: Detected)
Bit 6: PF3 detection (0: Not detected, 1: Detected)
Bit 7: Reserved.
B.2 Parameter Tables
Analog
Output
Level
No signal
output
available
YAI
No signal
output
available
No signal
output
available
10 V: 100%
10 V: 100%
10 V: 100%
No signal
output
available
Unit
0.1%
0.1%
0.1%
B
189