Engine Starting System; Electric Circuit - Kubota MX5100 Workshop Manual

Table of Contents

Advertisement

MX5100, WSM

2. ENGINE STARTING SYSTEM

[1] ELECTRIC CIRCUIT

(1) Battery
(2) Starter
(3) Slow Blow Fuse (50A)
(4) Starter Relay
No.
PTO Lever
"Disengaged" : PTO neutral switch "ON"
"Engaged" : PTO neutral switch "OFF"
1
"Disengaged"
2
"Disengaged"
3
"Engaged"
4
"Engaged"
When the PTO lever is set to "Disengaged" position and the synchro-shuttle shift lever is set to "Neutral" position,
the engine can be started.
(5) Fuse (5A)
(6) Slow Blow Fuse (50A)
(7) Key Switch
(8) PTO Neutral Switch 1
Synchro-Shuttle Shift Lever
1) Shift to "Forward" or "Reverse" position:
Shuttle lever neutral switch "OFF"
2) Shift to "Neutral" position :
Shuttle lever neutral switch "ON"
"Neutral"
"Forward" or "Reverse"
"Neutral"
"Forward" or "Reverse"
(9) PTO Neutral Switch 2
(10) Shuttle Lever Neutral Switch 1
(11) Shuttle Lever Neutral Switch 2
(12) Seat Switch
1) Can start : Battery current through both
2) Can not start : No battery current to
Can start
Can not start
Can not start
Can not start
9-M3
ELECTRICAL SYSTEM
a : Seated
b : Vacant
c : Turn Over
Engine Starting
switches to starter relay and starter
starter relay and starter
W1014010

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents