Allen-Bradley PowerFlex 525 User Manual page 147

Adjustable frequency ac drive
Hide thumbs Also See for PowerFlex 525:
Table of Contents

Advertisement

Category
Specifications
Encoder
Type:
Supply:
Quadrature:
Duty Cycle:
Requirements:
Control
Relay:
Outputs
Opto:
Analog
PowerFlex 525 Estimated Watts Loss (Rated Load, Speed & PWM)
Voltage
Output Current (A)
100...120V,
2.5
50/60 Hz 1-Phase
4.8
6.0
200...240V,
2.5
50/60 Hz 1-Phase
4.8
8.0
11.0
200...240V,
2.5
50/60 Hz 1-Phase
4.8
w/ EMC Filter
8.0
11.0
200...240V,
2.5
50/60 Hz 3-Phase
5.0
8.0
11.0
17.5
24.0
32.2
48.3
62.1
Rockwell Automation Publication 520-UM001A-EN-E - February 2013
Supplemental Drive Information
Incremental, dual channel
12V, 250 mA.
90 °, ±27 ° @ 25 °C.
50%, +10%
Encoders must be line driver type, quadrature (dual
channel) or pulse (single channel), 3.5...26V DC output,
single-ended or differential and capable of supplying a
minimum of 10 mA per channel. Allowable input is DC up to
a maximum frequency of 250 kHz. The encoder I/O
automatically scales to allow 5V, 12V and 24V DC nominal
voltages.
Quantity:
(2) 1 Programmable Form A and 1 Programmable Form B
Specification
Resistive Rating:
3.0 A @ 30V DC, 3.0 A @ 125V, 3.0 A @ 240V AC
Inductive Rating:
0.5 A @ 30V DC, 0.5 A @ 125V, 0.5 A @ 240V AC
Quantity:
(2) Programmable
Specification:
30V DC, 50 mA Non-inductive
Quantity:
(1) Non-Isolated 0-10V or 4-20 mA
Specification
Resolution:
10-bit
0-10V DC Analog:
1 k ohm minimum
4-20 mA Analog:
525 ohm maximum
Total Watts Loss
27.0
53.0
67.0
29.0
50.0
81.0
111.0
29.0
53.0
84.0
116.0
29.0
50.0
79.0
107.0
148.0
259.0
323.0
584.0
708.0
Appendix A