SERVICE PROGRAMMING

Setting the display temperature format

Follow the steps below to set the display temperature units (Celsius or Fahrenheit):
LANGUAGE
XX
Fig. 01
TEMPERATURE ºC / F
ºX
Fig. 02

Adjusting the boiler operating temperature

Follow the steps below to adjust the normal boiler operating temperature:
LANGUAGE
XX
Fig. 03
BOILER TEMP.
XXXºC
XXXºF
Fig. 04
Note:
i
By default, the boiler operating temperature is set to 118ºC / 244ºF. Any adjustments should be based
on the elevation that the machine will be used at (higher elevations may require lower temperatures)
and the type/brand of coffee capsule to be used.
1. Enter the Service Menu menu (see Fig. 01).
2. Press + until the display shows TEMPERATURE ºC / F (see Fig. 02),
3. Press OK. The current setting will flash. Press
4. When the desired setting is input, press OK to confirm, then press + to
return to the Service Menu.
1. Enter the Service Menu menu (see Fig. 03).
2. Press + until the display shows BOILER TEMP. XXX ºC / F (see Fig. 06),
3. Press OK. The current temperature setting will flash. Press
change it.
4. When the desired setting is input, press OK to confirm then press + to
return to the Service Menu.
QUARTZ
ONE TOUCH
or - to adjust it.
+
or - to
+