SERVICE PROGRAMMING
Maintenance cycles
Follow the steps below to adjust the number of beverages between maintenance alerts: (The machine can still be
used after the alarm sounds simply by silencing the alarm. The alarm is only intended to alert the user that the
routine maintenance is due.)
LANGUAGE
XX
Fig. 01
MAINTENAN. CYCLES
NO
Fig. 02
Note:
i
By default, the routine maintenance alarm is turned off (setting: NO). The setting should be determined
based on your intended use of the machine (coffees per day, public or wait staff-only accessibility, vendor
leasing or private ownership, etc.) Routine maintenance is intended to include replacement of shower
plates, gaskets, and other wearable items inside the group, and guarantees the machine continues to make
high-quality, well-extracted coffee.
28
1. Enter the Service Menu menu (see Fig. 01).
2. Press + until the display shows MAINTENAN. CYCLES NO or X000 (see
Fig. 02).
3. Press OK. The current setting will flash. Press
maintenance interval is adjustable from NO to 10,000 coffees, at
1,000 coffee intervals.
4. When the desired setting is input, press OK to confirm then press + to
return to the Service Menu.