Connect power to the laser system network switch

Turn the laser system network switch on before turning the laser modules on, so that the
system can find the laser modules.
1. Connect the 15 A power line from the wall outlet to the laser system network switch.

Install laser modules

Failure to comply with the following could result in death or serious injury.
• Do not service the laser module; the inner compartment contains Class 4 laser light.
• Place each laser module in the lowest available slot to maintain stability of the laser rack.
• Two or more people are required to safely lift a laser module.
• The laser module is not serviceable. Do not remove covers, use a replacement module
1. Remove the four screws securing the front panel on the bottom slot in the laser rack.
CP42LH Installation Guide
020-101373-02 Rev. 1 (06-2015)
Maximum power: 64 W, Wavelength: 435 nm–660 nm, Pulse Pattern: Continuous Wave
(CW).
If lower slots are skipped, the laser rack becomes top-heavy and could fall.
instead.