Connect Sources; Calibrate Color; Create Channels - Christie CP42LH Installation Manual

Hide thumbs Also See for CP42LH:
Table of Contents

Advertisement

Field
SNMP V2 / SNMP V3
Management IP
Download MIB to USB
Apply
Serial Access
Ethernet Access

Connect sources

1. Tap Menu > Administrator Setup > Communications Configuration.
2. In IP Address field, type the Ethernet settings.
3. In the Serial Speed (Baud) list, select a baud rate for the input device.
4. Tap Apply.

Calibrate color

1. To determine the Measured Color Gamut Data (MCGD) value, measure the colors displayed on
the screen from the center of the audience viewing location.
2. On the TPC, tap Menu > Advanced Setup > MCGD File Setup and enter the color values in
the x and y fields for the different colors.
3. Tap Save.
The software determines the Target Color Gamut Data (TCGD) value, which determines the
corrections needed to display the correct colors.

Create channels

Channels store customized projector settings for different inputs. You can create up to 64 channels.
1. In the Channel Name field, type the name.
2. To specify general settings, tap Config 1.
3. To specify color settings, tap Config 2.
4. To specify 3D settings, tap 3D Control.
5. To use this channel, click Activate.
CP42LH Installation Guide
020-101373-02 Rev. 1 (06-2015)
Description
The SNMP protocol type. Contact Christie technical support for the SNMP V3
user ID and password.
The IP address where SNMP information and notifications are sent.
Sends the SNMP Management Information Base (MIB) file to a USB flash
drive.
Applies SNMP settings.
Grants access to serial connections.
Grants access to Ethernet connections.
Adjust the Image
69

Advertisement

Table of Contents
loading