AMX TPI-PRO-2 Operation/Reference Manual page 176

Total presentation interface
Hide thumbs Also See for TPI-PRO-2:
Table of Contents

Advertisement

Upgrading Firmware
FIG. 87
NetLinx Studio - warning dialog
This is to alert you to the fact that configuration settings for an active system have been changed, while
connected to a NetLinx Master.
In order for the new settings to be applied, communications between the PC and the Master will be
stopped, then restarted using the new settings.
Click Yes to interrupt the current communication from the Master and apply the new settings.
11.
Open the Reboot the Master Controller dialog (Tools > Reboot the Master Controller), and click Reboot
to reboot the NetLinx Master and incorporate any changes (FIG. 88).
FIG. 88
NetLinx Studio - Reboot the Master Controller dialog
12.
When the dialog box replies with "Reboot of system complete", press Done.
13.
Click the OnLine Tree tab in the Workspace window to view the devices on the System. The default
System value is 1 (one).
14.
Right-click the Empty Device Tree/System entry, and select Refresh System to re-populate the list.