GE C30 Instruction Manual page 442

Ur series
Hide thumbs Also See for C30:
Table of Contents

Advertisement

E.1 DEVICE PROFILE DOCUMENT
Table E–2: IMPLEMENTATION TABLE (Sheet 3 of 4)
OBJECT
OBJECT
VARIATION
DESCRIPTION
NO.
NO.
23
5
32-Bit Frozen Counter Event with Time
cont'd
6
16-Bit Frozen Counter Event with Time
30
0
Analog Input (Variation 0 is used to request
default variation)
1
32-Bit Analog Input
2
16-Bit Analog Input
3
32-Bit Analog Input without Flag
4
16-Bit Analog Input without Flag
E
5
short floating point
32
0
Analog Change Event (Variation 0 is used
to request default variation)
1
32-Bit Analog Change Event without Time 1
2
16-Bit Analog Change Event without Time 1
3
32-Bit Analog Change Event with Time
4
16-Bit Analog Change Event with Time
5
short floating point Analog Change Event
without Time
7
short floating point Analog Change Event
with Time
34
0
Analog Input Reporting Deadband
(Variation 0 is used to request default
variation)
1
16-bit Analog Input Reporting Deadband
(default – see Note 1)
Note 1:
A default variation refers to the variation responded when variation 0 is requested and/or in class 0, 1, 2, or 3 scans. The default varia-
tions for object types 1, 2, 20, 21, 22, 23, 30, and 32 are selected via relay settings. Refer to the Communications section in Chapter 5
for details. This optimizes the class 0 poll data size.
Note 2:
For static (non-change-event) objects, qualifiers 17 or 28 are only responded when a request is sent with qualifiers 17 or 28, respec-
tively. Otherwise, static object requests sent with qualifiers 00, 01, 06, 07, or 08, will be responded with qualifiers 00 or 01 (for change-
event objects, qualifiers 17 or 28 are always responded.)
Note 3:
Cold restarts are implemented the same as warm restarts – the C30 is not restarted, but the DNP process is restarted.
E-6
REQUEST
FUNCTION
QUALIFIER
CODES (DEC)
CODES (HEX)
1
06
(read)
(no range, or all)
07, 08
1
06
(read)
(no range, or all)
07, 08
1
00, 01
(read)
22
06
(assign class)
(no range, or all)
07, 08
17, 28
1
00, 01
(read)
22
06
(assign class)
(no range, or all)
07, 08
17, 28
1
00, 01
(read)
22
06
(assign class)
(no range, or all)
07, 08
17, 28
1
00, 01
(read)
22
06
(assign class)
(no range, or all)
07, 08
17, 28
1
00, 01
(read)
22
06
(assign class)
(no range, or all)
07, 08
17, 28
1
00, 01
(read)
22
06
(assign class)
(no range, or all)
07, 08
(limited quantity)
17, 28
(index)
1
06
(read)
(no range, or all)
07, 08
06
(read)
(no range, or all)
07, 08
06
(read)
(no range, or all)
07, 08
1
06
(read)
(no range, or all)
07, 08
1
06
(read)
(no range, or all)
07, 08
1
06
(read)
(no range, or all)
07, 08
1
06
(read)
(no range, or all)
07, 08
1
00, 01
(read)
06
(no range, or all)
07, 08
17, 28
1
00, 01
(read)
06
(no range, or all)
07, 08
17, 28
2
00, 01
(write)
07, 08
17, 28
C30 Controller System
APPENDIX E
RESPONSE
FUNCTION
QUALIFIER
CODES (DEC)
CODES (HEX)
129
17, 28
(response)
130
(limited quantity)
(unsol. resp.)
129
17, 28
(response)
130
(limited quantity)
(unsol. resp.)
(start-stop)
(limited quantity)
(index)
129
00, 01
(start-stop)
(response)
17, 28
(see Note 2)
(limited quantity)
(index)
129
00, 01
(start-stop)
(response)
17, 28
(see Note 2)
(limited quantity)
(index)
129
00, 01
(start-stop)
(response)
17, 28
(see Note 2)
(limited quantity)
(index)
129
00, 01
(start-stop)
(response)
17, 28
(see Note 2)
(limited quantity)
(index)
129
00, 01
(start-stop)
(response)
17, 28
(see Note 2)
(limited quantity)
129
17, 28
(response)
130
(limited quantity)
(unsol. resp.)
129
17, 28
(response)
130
(limited quantity)
(unsol. resp.)
129
17, 28
(response)
130
(limited quantity)
(unsol. resp.)
129
17, 28
(response)
130
(limited quantity)
(unsol. resp.)
129
17, 28
(response)
130
(limited quantity)
(unsol. resp.)
129
17, 28
(response)
130
(limited quantity)
(unsol. resp.)
(start-stop)
(limited quantity)
(index)
129
00, 01
(start-stop)
(response)
17, 28
(see Note 2)
(limited quantity)
(index)
(start-stop)
(limited quantity)
(index)
(index)
(index)
(start-stop)
(index)
(start-stop)
(index)
(start-stop)
(index)
(start-stop)
(index)
(start-stop)
(index)
(index)
(index)
(index)
(index)
(index)
(index)
(start-stop)
(index)
GE Multilin

Advertisement

Table of Contents
loading

Table of Contents