B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 4 of 47)
ADDR
REGISTER NAME
1606
Field Shared Output Operand States
1607
Field Latching Output Open Operand States
1608
Field Latching Output Close Operand States
1609
Field Latching Output Open Driver States
160A
Field Latching Output Close Driver States
B
160B
Field Latching Output Physical States
160C
Field Unit Online/Offline States
160D
Field RTD Input Trouble States
160E
Field Transducer Input Trouble States
Ethernet Fibre Channel Status (Read Only)
1610
Ethernet Primary Fibre Channel Status
1611
Ethernet Secondary Fibre Channel Status
Data Logger Actual Values (Read Only)
1618
Data Logger Channel Count
1619
Time of Oldest Available Samples
161B
Time of Newest Available Samples
161D
Data Logger Duration
Field Unit RTD Actuals (Read Only) (8 modules)
16C0
Field RTD 1 Value
16C1
...Repeated for Field RTD 2
16C2
...Repeated for Field RTD 3
16C3
...Repeated for Field RTD 4
16C4
...Repeated for Field RTD 5
16C5
...Repeated for Field RTD 6
16C6
...Repeated for Field RTD 7
16C7
...Repeated for Field RTD 8
Field Unit Transducer Actuals (Read Only) (8 modules)
16C8
Field Transducer 1 Value
16CA
...Repeated for Field Transducer 2
16CC
...Repeated for Field Transducer 3
16CE
...Repeated for Field Transducer 4
16D0
...Repeated for Field Transducer 5
16D2
...Repeated for Field Transducer 6
16D4
...Repeated for Field Transducer 7
16D6
...Repeated for Field Transducer 8
Passwords Unauthorized Access (Read/Write Command)
2230
Reset Unauthorized Access
Filed Unit Raw Data Settings (Read/Write Setting)
2460
Field Raw Data Port
2461
Filed Raw Data Freeze
Remote Double-Point Status Inputs (Read/Write Setting Registers) (5 modules)
2620
Remote Double-Point Status Input 1 Device
2621
Remote Double-Point Status Input 1 Item
2622
Remote Double-Point Status Input 1 Name
2628
Remote Double-Point Status Input 1 Events
2629
... Repeated for Double-Point Status Input 2
2632
... Repeated for Double-Point Status Input 3
263B
... Repeated for Double-Point Status Input 4
2644
... Repeated for Double-Point Status Input 5
IEC 61850 GGIO5 Configuration (Read/Write Setting Registers) (16 modules)
26B0
IEC 61850 GGIO5 uinteger Input 1 Operand
26B1
IEC 61850 GGIO5 uinteger Input 2 Operand
26B2
IEC 61850 GGIO5 uinteger Input 3 Operand
26B3
IEC 61850 GGIO5 uinteger Input 4 Operand
B-12
RANGE
UNITS
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 2
0 to 2
0 to 16
channel
0 to 4294967295
seconds
0 to 4294967295
seconds
0 to 999.9
days
-32768 to 32767
-32.768 to 32.767
0 to 1
0 to 7
0 to 1
1 to 32
0 to 64
1 to 64
0 to 1
---
---
---
---
C30 Controller System
APPENDIX B
STEP
FORMAT
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F134
---
1
F134
1
F001
1
F050
1
F050
0.1
F001
°C
1
F002
---
0.001
F004
---
1
F126
---
1
F244
---
1
F102
---
1
F001
---
1
F606
---
1
F205
"RemDPS Ip 1"
---
1
F102
---
---
F612
---
---
F612
---
---
F612
---
---
F612
DEFAULT
0
0
0
0
0
0
0
0
0
0 (Fail)
0 (Fail)
0
0
0
0
0
0
0 (No)
6 (H1a)
0 (Disabled)
1
0 (None)
0 (Disabled)
0
0
0
0