B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 30 of 47)
ADDR
REGISTER NAME
AF13
IEC 61850 GGIO4 Analog Input 1 Minimum
AF15
IEC 61850 GGIO4 Analog Input 1 Maximum
AF17
...Repeated for IEC 61850 GGIO4 Analog Input 2
B
AF1E
...Repeated for IEC 61850 GGIO4 Analog Input 3
AF25
...Repeated for IEC 61850 GGIO4 Analog Input 4
AF2C
...Repeated for IEC 61850 GGIO4 Analog Input 5
AF33
...Repeated for IEC 61850 GGIO4 Analog Input 6
AF3A
...Repeated for IEC 61850 GGIO4 Analog Input 7
AF41
...Repeated for IEC 61850 GGIO4 Analog Input 8
AF48
...Repeated for IEC 61850 GGIO4 Analog Input 9
AF4F
...Repeated for IEC 61850 GGIO4 Analog Input 10
AF56
...Repeated for IEC 61850 GGIO4 Analog Input 11
AF5D
...Repeated for IEC 61850 GGIO4 Analog Input 12
AF64
...Repeated for IEC 61850 GGIO4 Analog Input 13
AF6B
...Repeated for IEC 61850 GGIO4 Analog Input 14
AF72
...Repeated for IEC 61850 GGIO4 Analog Input 15
AF79
...Repeated for IEC 61850 GGIO4 Analog Input 16
AF80
...Repeated for IEC 61850 GGIO4 Analog Input 17
AF87
...Repeated for IEC 61850 GGIO4 Analog Input 18
AF8E
...Repeated for IEC 61850 GGIO4 Analog Input 19
AF95
...Repeated for IEC 61850 GGIO4 Analog Input 20
AF9C
...Repeated for IEC 61850 GGIO4 Analog Input 21
AFA3
...Repeated for IEC 61850 GGIO4 Analog Input 22
AFAA
...Repeated for IEC 61850 GGIO4 Analog Input 23
AFB1
...Repeated for IEC 61850 GGIO4 Analog Input 24
AFB8
...Repeated for IEC 61850 GGIO4 Analog Input 25
AFBF
...Repeated for IEC 61850 GGIO4 Analog Input 26
AFC6
...Repeated for IEC 61850 GGIO4 Analog Input 27
AFCD
...Repeated for IEC 61850 GGIO4 Analog Input 28
AFD4
...Repeated for IEC 61850 GGIO4 Analog Input 29
AFDB
...Repeated for IEC 61850 GGIO4 Analog Input 30
AFE2
...Repeated for IEC 61850 GGIO4 Analog Input 31
AFE9
...Repeated for IEC 61850 GGIO4 Analog Input 32
IEC 61850 GOOSE/GSSE Configuration (Read/Write Setting)
B01C
Default GOOSE/GSSE Update Time
B01D
IEC 61850 GSSE Function (GsEna)
B01E
IEC 61850 GSSE ID
B03F
IEC 61850 GOOSE Function (GoEna)
B040
IEC 61850 GSSE Destination MAC Address
B043
IEC 61850 Standard GOOSE ID
B064
IEC 61850 Standard GOOSE Destination MAC Address
B067
IEC 61850 GOOSE VLAN Transmit Priority
B068
IEC 61850 GOOSE VLAN ID
B069
IEC 61850 GOOSE ETYPE APPID
B06A
Reserved (2 items)
IEC 61850 Server Configuration (Read/Write Settings/Commands)
B06C
TCP Port Number for the IEC 61850 / MMS Protocol
B06D
IEC 61850 Logical Device Name
B07D
IEC 61850 Logical Device Instance
B08D
IEC 61850 LPHD Location
B0B5
Include Non-IEC 61850 Data
B06B
IEC 61850 Server Data Scanning Function
B0B7
Reserved (9 items)
B-38
RANGE
UNITS
–1000000000000 to
1000000000000
–1000000000000 to
1000000000000
1 to 60
0 to 1
---
0 to 1
---
---
---
0 to 7
0 to 4095
0 to 16383
0 to 1
1 to 65535
---
---
0 to 65534
0 to 1
0 to 1
0 to 1
C30 Controller System
APPENDIX B
STEP
FORMAT
---
0.001
F060
---
0.001
F060
s
1
F001
---
1
F102
---
---
F209
---
1
F102
0 (Disabled)
---
---
F072
---
---
F209
"GOOSEOut"
---
---
F072
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
---
F213
---
---
F213
---
1
F204
---
1
F102
0 (Disabled)
---
1
F102
0 (Disabled)
---
1
F001
DEFAULT
0
1000000
60
1 (Enabled)
"GSSEOut"
0
0
4
0
0
0
102
"IEDName"
"LDInst"
"Location"
0
GE Multilin