APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 29 of 47)
ADDR
REGISTER NAME
AB2D
Command to Clear XCBR5 OpCnt (Operation Counter)
AB2E
Operand for IEC 61850 XCBR6.ST.Loc Status
AB2F
Command to Clear XCBR6 OpCnt (Operation Counter)
IEC 61850 LN Name Prefixes (Read/Write Settings)
AB30
IEC 61850 Logical Node LPHD1 Name Prefix
AB33
IEC 61850 Logical Node PIOCx Name Prefix (72 items)
AC0B
IEC 61850 Logical Node PTOCx Name Prefix (24 items)
AC53
IEC 61850 Logical Node PTUVx Name Prefix (13 items)
AC7A
IEC 61850 Logical Node PTOVx Name Prefix (10 items)
AC98
IEC 61850 Logical Node PDISx Name Prefix (10 items)
ACB6
IEC 61850 Logical Node RBRFx Name Prefix (24 items)
ACFE
IEC 61850 Logical Node RPSBx Name Prefix
AD01
IEC 61850 Logical Node RRECx Name Prefix (6 items)
AD13
IEC 61850 Logical Node MMXUx Name Prefix (6 items)
AD25
IEC 61850 Logical Node GGIOx Name Prefix (5 items)
AD34
IEC 61850 Logical Node RFLOx Name Prefix (5 items)
AD43
IEC 61850 Logical Node XCBRx Name Prefix (6 items)
AD55
IEC 61850 Logical Node PTRCx Name Prefix (6 items)
AD67
IEC 61850 Logical Node PDIFx Name Prefix (4 items)
AD73
IEC 61850 Logical Node MMXNx Name Prefix (37
items)
ADE2
IEC 61850 Logical Node CSWIx Name Prefix (30 items)
AE3C
IEC 61850 Logical Node XSWIx Name Prefix (24 items)
IEC 61850 XSWI Configuration (Read/Write Settings and Commands) (24 modules)
AECF
FlexLogic Operand for IEC 61850 XSWI1.ST.Loc Status
AED0
Command to Clear XSWI1 OpCnt (Operation Counter)
AED1
Repeated for IEC 61850 XSWI2
AED3
Repeated for IEC 61850 XSWI3
AED5
Repeated for IEC 61850 XSWI4
AED7
Repeated for IEC 61850 XSWI5
AED9
Repeated for IEC 61850 XSWI6
AEDB
Repeated for IEC 61850 XSWI7
AEDD
Repeated for IEC 61850 XSWI8
AEDF
Repeated for IEC 61850 XSWI9
AEE1
Repeated for IEC 61850 XSWI10
AEE3
Repeated for IEC 61850 XSWI11
AEE5
Repeated for IEC 61850 XSWI12
AEE7
Repeated for IEC 61850 XSWI13
AEE9
Repeated for IEC 61850 XSWI14
AEEB
Repeated for IEC 61850 XSWI15
AEED
Repeated for IEC 61850 XSWI16
AEEF
Repeated for IEC 61850 XSWI17
AEF1
Repeated for IEC 61850 XSWI18
AEF3
Repeated for IEC 61850 XSWI19
AEF5
Repeated for IEC 61850 XSWI20
AEF7
Repeated for IEC 61850 XSWI21
AEF9
Repeated for IEC 61850 XSWI22
AEFB
Repeated for IEC 61850 XSWI23
AEFD
Repeated for IEC 61850 XSWI24
IEC 61850 GGIO4 General Analog Configuration Settings (Read/Write Setting)
AF00
Number of Analog Input Points in GGIO4
IEC 61850 GGIO4 Analog Input Points Configuration Settings (Read/Write Setting) (32 modules)
AF10
IEC 61850 GGIO4 Analog Input 1 Value
AF11
IEC 61850 GGIO4 Analog Input 1 Deadband
GE Multilin
RANGE
UNITS
0 to 1
0 to 65535
0 to 1
0 to 65534
0 to 65534
0 to 65534
0 to 65534
0 to 65534
0 to 65534
0 to 65534
0 to 65534
0 to 65534
0 to 65534
0 to 65534
0 to 65534
0 to 65534
0 to 65534
0 to 65534
0 to 65534
0 to 65534
0 to 65534
0 to 65535
0 to 1
4 to 32
---
0.001 to 100
C30 Controller System
B.4 MEMORY MAPPING
STEP
FORMAT
---
1
F126
---
1
F300
---
1
F126
---
1
F206
---
1
F206
---
1
F206
---
1
F206
---
1
F206
---
1
F206
---
1
F206
---
1
F206
---
1
F206
---
1
F206
---
1
F206
---
1
F206
---
1
F206
---
1
F206
---
1
F206
---
1
F206
---
1
F206
---
1
F206
---
1
F300
---
1
F126
---
4
F001
---
---
F600
%
0.001
F003
DEFAULT
0 (No)
0
0 (No)
(none)
B
(none)
(none)
(none)
(none)
(none)
(none)
(none)
(none)
(none)
(none)
(none)
(none)
(none)
(none)
(none)
(none)
(none)
0
0 (No)
4
0
100000
B-37

Advertisement

Table of Contents
loading