GE C30 Instruction Manual page 333

Ur series
Hide thumbs Also See for C30:
Table of Contents

Advertisement

APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 17 of 47)
ADDR
REGISTER NAME
4D00
...Repeated for User-Definable Display 9
4D20
...Repeated for User-Definable Display 10
4D40
...Repeated for User-Definable Display 11
4D60
...Repeated for User-Definable Display 12
4D80
...Repeated for User-Definable Display 13
4DA0
...Repeated for User-Definable Display 14
4DC0
...Repeated for User-Definable Display 15
4DE0
...Repeated for User-Definable Display 16
Field Unit Raw Data Actuals (Read Only) (8 modules)
4E00
Raw Field Data AC1 Mag
4E02
Raw Field Data AC1 Angle
4E03
Raw Field Data AC2 Mag
4E05
Raw Field Data AC2 Angle
4E06
Raw Field Data AC3 Mag
4E08
Raw Field Data AC3 Angle
4E09
Raw Field Data AC4 Mag
4E0B
Raw Field Data AC4 Angle
4E0C
Raw Field Data AC5 Mag
4E0E
Raw Field Data AC5 Angle
4E0F
Raw Field Data AC6 Mag
4E11
Raw Field Data AC6 Angle
4E12
Raw Field Data AC7 Mag
4E14
Raw Field Data AC7 Angle
4E15
Raw Field Data AC8 Mag
4E17
Raw Field Data AC8 Angle
4E18
Raw Field Data DC1
4E19
Raw Field Data DC2
4E1A
Raw Field Data DC3
4E1B
Raw Field Data FCI States (2 items)
4E1D
Raw Field Data SI States
4E1E
Raw Field Data SI Test States
4E1F
Raw Field Data Brick ADC Temperature
4E20
Raw Field Data Brick Transceiver Temperature
4E21
Raw Field Data Brick Transceiver Voltage
4E22
Raw Field Data Brick Transceiver Current
4E23
Raw Field Data Brick Tx Power
4E24
Raw Field Data Brick Rx Power
4E25
Raw Field Data Brick Diagnostics (2 items)
4E27
Raw Field Data Local Transceiver Temperature
4E28
Raw Field Data Local Transceiver Voltage
4E29
Raw Field Data Local Transceiver Current
4E2A
Raw Field Data Local Tx Power
4E2B
Raw Field Data Local Rx Power
4E2C
Repeated for Field Unit 2
4E58
Repeated for Field Unit 3
4E84
Repeated for Field Unit 4
4E80
Repeated for Field Unit 5
4EDC
Repeated for Field Unit 6
4F08
Repeated for Field Unit 7
4F34
Repeated for Field Unit 8
FlexLogic (Read/Write Setting)
5000
FlexLogic™ Entry (512 items)
RTD Inputs (Read/Write Setting) (48 modules)
5400
RTD Input 1 Function
GE Multilin
RANGE
UNITS
0 to 0.001
0 to 0.1
degree
0 to 0.001
0 to 0.1
degree
0 to 0.001
0 to 0.01
degree
0 to 0.001
0 to 0.01
degree
0 to 0.001
0 to 0.01
degree
0 to 0.001
0 to 0.01
degree
0 to 0.001
0 to 0.01
degree
0 to 0.001
0 to 0.01
degree
0 to 0.001
0 to 0.001
0 to 0.001
0 to 1
0 to 1
0 to 1
0 to 1
degree
0 to 1
degree
0 to 0.01
0 to 1
0 to 0.1
0 to 0.1
0 to 65535
0 to 1
degree
0 to 0.01
0 to 1
0 to 0.1
0 to 0.1
0 to 65535
0 to 1
C30 Controller System
B.4 MEMORY MAPPING
STEP
FORMAT
A
0.001
F003
0.1
F002
A
0.001
F003
0.1
F002
A
0.001
F003
0.1
F002
A
0.001
F003
0.1
F002
A/V
0.001
F003
0.1
F002
A/V
0.001
F003
0.1
F002
A/V
0.001
F003
0.1
F002
A/V
0.001
F003
0.1
F002
V
0.001
F002
V
0.001
F002
V
0.001
F002
---
1
F500
---
1
F500
---
1
F500
1
F002
1
F002
V
0.01
F001
mA
1
F001
dBm
0.1
F002
dBm
0.1
F002
---
1
F500
1
F002
V
0.01
F001
mA
1
F001
dBm
0.1
F002
dBm
0.1
F002
---
1
F300
---
1
F102
DEFAULT
B
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
8192
0 (Disabled)
B-25

Advertisement

Table of Contents
loading

Table of Contents