GE C30 Instruction Manual page 328

Ur series
Hide thumbs Also See for C30:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 12 of 47)
ADDR
REGISTER NAME
3F89
...Repeated for Field Unit 2
3F92
...Repeated for Field Unit 3
3F9B
...Repeated for Field Unit 4
3FA4
...Repeated for Field Unit 5
3FAD
...Repeated for Field Unit 6
B
3FB6
...Repeated for Field Unit 7
3FBF
...Repeated for Field Unit 8
Passwords (Read/Write Command)
4000
Command Password Setting
Passwords (Read/Write Setting)
4002
Setting Password Setting
Passwords (Read/Write)
4008
Command Password Entry
400A
Setting Password Entry
Passwords (Read Only Actual Values)
4010
Command Password Status
4011
Setting Password Status
Passwords (Read/Write Settings)
4012
Command Password Access Timeout
4013
Setting Password Access Timeout
4014
Invalid Password Attempts (before lockout)
4015
Password Lockout Duration
4016
Password Access Events
4017
Local Setting Authorization
4018
Remote Setting Authorization
4019
Access Authorization Timeout
User Display Invoke (Read/Write Setting)
4040
Invoke and Scroll Through User Display Menu Operand
LED Test (Read/Write Setting)
4048
LED Test Function
4049
LED Test Control
Preferences (Read/Write Setting)
404F
Language
4050
Flash Message Time
4051
Default Message Timeout
4052
Default Message Intensity
4053
Screen Saver Feature
4054
Screen Saver Wait Time
4055
Current Cutoff Level
4056
Voltage Cutoff Level
Communications (Read/Write Setting)
407D
COM2 Selection
407E
COM1 Minimum Response Time
407F
COM2 Minimum Response Time
4080
Modbus Slave Address
4083
RS485 Com1 Baud Rate
4084
RS485 Com1 Parity
4085
RS485 Com2 Baud Rate
4086
RS485 Com2 Parity
4087
IP Address
4089
IP Subnet Mask
408B
Gateway IP Address
408D
Network Address NSAP
409A
DNP Channel 1 Port
B-20
RANGE
UNITS
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 1
0 to 1
5 to 480
minutes
5 to 480
minutes
2 to 5
5 to 60
minutes
0 to 1
1 to 65535
0 to 65535
5 to 480
minutes
0 to 65535
0 to 1
0 to 65535
0 to 4
0.5 to 10
10 to 900
0 to 3
0 to 1
1 to 65535
0.002 to 0.02
0.1 to 1
0 to 3
0 to 1000
0 to 1000
1 to 254
0 to 11
0 to 2
0 to 11
0 to 2
0 to 4294967295
0 to 4294967295
0 to 4294967295
---
0 to 5
C30 Controller System
APPENDIX B
STEP
FORMAT
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F102
---
1
F102
1
F001
1
F001
---
1
F001
1
F001
---
1
F102
---
1
F300
---
1
F300
1
F001
---
1
F300
---
1
F102
---
1
F300
---
1
F531
s
0.1
F001
s
1
F001
---
1
F101
---
1
F102
min
1
F001
pu
0.001
F001
V
0.1
F001
---
1
F601
ms
10
F001
ms
10
F001
---
1
F001
---
1
F112
---
1
F113
---
1
F112
---
1
F113
---
1
F003
---
1
F003
---
1
F003
---
---
F074
---
1
F177
DEFAULT
0
0
0
0
0 (Disabled)
0 (Disabled)
5
30
3
5
0 (Disabled)
1
1
30
0
0 (Disabled)
0
0 (English)
10
300
0 (25%)
0 (Disabled)
30
20
10
0 (RS485)
0
0
254
8 (115200)
0 (None)
8 (115200)
0 (None)
56554706
4294966272
56554497
0
0 (None)
GE Multilin

Advertisement

Table of Contents
loading

Table of Contents