Replacing Power System Components; Gateway - Juniper SRX550 Hardware Manual

Highmemoryservicesgateway
Hide thumbs Also See for SRX550:
Table of Contents

Advertisement

CHAPTER 22

Replacing Power System Components

Replacing the AC Power Supply on the SRX550 High Memory Services Gateway
Disconnecting an AC Power Cord from the SRX550 High Memory Services Gateway
Copyright © 2016, Juniper Networks, Inc.
Replacing the AC Power Supply on the SRX550 High Memory Services
Gateway on page 161
Replacing a DC Power Supply on the SRX550 High Memory Services
Gateway on page 165
You can replace the AC power supply on the SRX550 High Memory Services Gateway
after disconnecting the AC power cord and removing the power supply already installed.
However, redundant AC power supplies are hot-swappable. You need not power off the
services gateway for replacing them.
NOTE:
To maintain proper cooling and prevent thermal shutdown of the
operating power supply unit, each power supply slot must contain either a
power supply or a blank panel. If you remove a power supply, you must install
a replacement power supply or a blank panel shortly after the removal.
This topic describes:
Disconnecting an AC Power Cord from the SRX550 High Memory Services
Gateway on page 161
Removing an AC Power Supply from the SRX550 High Memory Services
Gateway on page 162
Installing an AC Power Supply on the SRX550 High Memory Services
Gateway on page 163
Connecting an AC Power Cord to the SRX550 High Memory Services
Gateway on page 164
WARNING:
Before working on an AC-powered device or near power supplies,
unplug the power cord.
161