System Bring-Up; Configuring Network Attributes; Table 10: Serial Terminal Program Configuration - Mellanox Technologies SX10XX Hardware User Manual

1u switch systems
Table of Contents

Advertisement

2.9

System Bring-Up

2.9.1

Configuring Network Attributes

The procedures described in this chapter assume that you have already installed and powered-on
according to the instructions in this document.
 To perform initial configuration of the system, perform the following:
Connect a host PC to the Console RJ45
Step 1.
cable (DB9 to RJ45). Make sure to connect to the Console RJ45 port and not to the (Ethernet)
MGT port.
Configure a serial terminal program (for example, HyperTerminal, minicom, or Tera Term) on
Step 2.
your host PC with the settings described in
CLI prompt of the system.
Table 10 - Serial Terminal Program Configuration
Baud Rate
Data bits
Stop bits
Parity
Flow Control
Login as admin and use admin as password. On the first login, the MLNX-OS configuration
Step 3.
wizard will start.
To configure network attributes and other initial parameters to the system, follow the configu-
Step 4.
ration wizard as shown in
34
Mellanox Technologies
The bring-up procedures described in this section do not apply to managed systems.
Such systems are ready for operation after power-on.
Parameter
9600 or 115200 (see below)
8
1
None
None
The baud rate is different per CPU type of the system.
The systems based on x86 CPU (SX1700, SX1400) should be configured with baud
rate = 115200, while the rest of the systems (based on PPC460),should be configured
with 9600.
Table
port of the system using the supplied harness
Table
10. Once you perform that, you should get the
Setting
11.
Installation

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sx1x00

Table of Contents