NCU Parameters

Address
Function
Sweden
Switzerland
Portugal
Holland
Spain
Israel
Address
Function
680501
Line current detection time
680502
Line current wait time
680503
Line current drop detect time
PSTN dial tone frequency upper
680504
limit (high byte)
PSTN dial tone frequency upper
680505
limit (low byte)
PSTN dial tone frequency lower
680506
limit (high byte)
PSTN dial tone frequency lower
680507
limit (low byte)
680508
PSTN dial tone detection time
680509
PSTN dial tone reset time (LOW)
68050A
PSTN dial tone reset time (HIGH)
PSTN dial tone continuous tone
68050B
time
D127/D128
10
0A
Korea
11
0B
Brazil
Turkey
12
0C
Greece
13
0D
Hungary
14
0E
Czech
15
0F
Poland
Unit
20 ms
Hz (BCD)
Hz (BCD)
20 ms
5-70
28
1C
29
1D
32
20
33
21
34
22
35
23
36
24
Remarks
Line current detection is
disabled.
Line current is not
detected if 680501
contains FF.
If both addresses
contain FF(H), tone
detection is disabled.
If both addresses
contain FF(H), tone
detection is disabled.
If 680508 contains
FF(H), the machine
pauses for the pause
time (address 68050D /
68050E).
Italy: See Note 2.