No.
Definition
White level correction error
The automatic adjustment has
142
B
failed to correct a current white
level to the certain level.
SBU Communication Error
144
B
Cannot correctly establish
communication with the SBU.
161
IPU error
LSYNC error
-001
B
Detecting an error from the result of
the IPU self-check on startup.
RI response error
-002
B
Detecting an error on access to the
RI.
SM
Symptom
6-3
Possible Cause
Dewing scanner unit
Defective scanner drive
Defective optical section
Defective SBU board
Defective relevant harness
Defective relevant harness
Defective destination device
(e.g., BICU, etc)
Defective SBU
Defective the IPU or the BICU
(or bad connection between the
ASIC and the LEO, LSYNC
Abnormal, etc)
Cable bad connection between
the SBU and the IPU (or the
BICU).
Defective the IPU (the BICU, the
ICTL) or RI abnormal
performance, etc
SC Tables
D127/D128