Ricoh D127 Service Manual page 508

Hide thumbs Also See for D127:
Table of Contents

Advertisement

Bit Switches
3
Not used
Maximum allowable frame
interval during image data
4
reception.
0: 5 sec 1: 13 sec
5
Not used
Reconstruction time for the first
6
line in receive mode
0: 6 sec 1: 12 sec
7
Not used
G3 Switch 0B Not used (do not change the settings).
D127/D128
Do not change the settings
This bit set the maximum interval between EOL
(end-of-line) signals and the maximum interval
between ECM frames from the other end.
Try using a longer setting if error code 0-21 is
frequent.
Do not change the settings.
When the sending terminal is controlled by a
computer, there may be a delay in receiving
page data after the local machine accepts
set-up data and sends CFR. This is outside the
T.30 recommendation. But, if this delay occurs,
set this bit to 1 to give the sending machine
more time to send data.
Refer to error code 0-20.
ITU-T T.30 recommendation: The first line
should come within 5 s of CFR.
Do not change the settings.