No.
Definition
Polygon motor error: Time out (Off)
203
B
NOT XSCRDY signal becoming "H"
(Inactive) within three seconds.
Polygon motor error: XSCRDY signal error
204
B
Detecting XSCRDY signal "H"
(Inactive) while writing.
LD synchro-detection error
NOT output certain
220
B
syncro-detection signal within
200ms after LD lighting in
steady-rotation.
SM
Symptom
6-5
Possible Cause
Harness and the polygon motor
driver.
Defective the polygon motor or
the polygon motor driver.
Defective polygon motor drive
pulse output (Around polygon
control parts)
Unable to monitor XSCRDY
signal (Around polygon control
parts)
Bad connection or
disconnection between the I/F
Harness and the polygon motor
driver.
Defective the polygon motor or
the polygon motor driver.
Bad connection or
disconnection between the I/F
Bad connection or
disconnection between the I/F
harness and the
syncro-detection Unit.
Defective the syncro-detection
NOT the beam going into the
photo detector
Defective the GAVD related
parts, the LD driver, the LDB,
the BICU