Ricoh D127 Service Manual page 174

Hide thumbs Also See for D127:
Table of Contents

Advertisement

SC Tables
No.
Definition
Development bias error
The maximum rate of PWM duty
(50%) occurs 10 times in series
391
B
(20msec x 10)
This error doesn't happen when the
front door (the inter lock) opens.
Developer initialization error
The P sensor does not detect a
correct pattern during developer
initialization (SP2-801-001).
392
B
When Vsp output is more than
2.5V, SC appears in the case of not
removing the heat seal or an
absence of developer.
Transfer roller leak error (positive electrode)
The feedback voltage of the
transfer roller has been more
than the certain voltage for
200msec. (Open detecting
condition)
401
B
The feedback voltage of the
transfer roller has been
insufficient for 200msec. (Leak
detecting condition)
This error doesn't happen when the
front door (the inter lock) opens.
D127/D128
Symptom
6-8
Possible Cause
Defective the MD
Defective harness connected to
the HVP
Defective P sensor
Defective T sensor
NOT removing heat-seal
Defective drum operation
Defective development roller
operation
Defective harness connected to
HVP
Defective the MD
SM