No.
Definition
Time out error
(On the fusing roller inactive)
NOT reaching the reload
temperature in 25 seconds after
-003
A
starting heater control.
(On the fusing roller active)
NOT reaching the reload
temperature in 35 seconds after
starting heater control.
Fusing overheat error 1
The fusing temperature detected by
543
A
the thermistor is 230°C or higher for
one second.
Fusing overheat error 2
The fusing temperature detected by
544
A
the monitor circuit is 250°C or
higher.
Fusing lamp overheat error
The fusing lamp remains on for 12
545
A
seconds after starting the waiting
mode.
547
Zero cross signal malfunction
-001
B
Detecting fusing contact meltdown
SM
Symptom
6-11
Possible Cause
Disconnection of Heater After
activation of the anti-overheat
device
Defective the triac
(Semiconductor device)
Defective the IOB control board
Detective the BICU control
board
Defective the triac
(Semiconductor device)
Defective the IOB control board
Defective the BICU control
board
Uncontrollable fusing condition
Defective thermistor
Disconnection of Heater
After activation of the
anti-overheat device
Defective the fusing relay
SC Tables