Field
State

Displaying the power module operating status

Use the display power command to display the power module operating status.
<Sysname> display power
System Power Total
System Power Used
System Power Usable
Power No.
---------------------------------------------
1
2
Table 17 Command output
Field
System Power Total
System Power Used
System Power Usable
Power No.
Type
Watts
ID
State

Displaying the alarming thresholds of a card

Use the display environment command to display the temperature information and alarming thresholds
of a card.
<Sysname> display environment
Temperature information (degree centigrade):
----------------------------------------------------------
SlotNo
Description
Fan state:
Type
Watts
N/A
N/A
AC
650
Description
Total power provided by the power modules.
Power in use.
Power available for use.
Slot number of the power module.
Power module type:
Power provided by the power module.
Power module ID.
Power module state:
Temperature
Lower limit
Normal—The fan is operating correctly.
Absent—The fan is not in position.
Fault—The fan has failed.
: 650
watts
: 275
watts
: 375
watts
State
ID
Absent
N/A
Normal
0
AC—AC power modules.
DC—DC power modules.
Normal—The power module is operating correctly.
Absent—The power module is not in position.
Fault—The power module has failed.
Upper limit
61