User-Programmable Self Tests - GE D30 Instruction Manual

Line distance protection system
Hide thumbs Also See for D30:
Table of Contents

Advertisement

CHAPTER 5: SETTINGS
Table 5-12: Recommended settings for user-programmable LEDs
Setting
Parameter
LED 1 operand
SETTING GROUP ACT 1
LED 2 operand
SETTING GROUP ACT 2
LED 3 operand
SETTING GROUP ACT 3
LED 4 operand
SETTING GROUP ACT 4
LED 5 operand
SETTING GROUP ACT 5
LED 6 operand
SETTING GROUP ACT 6
LED 7 operand
Off
LED 8 operand
Off
LED 9 operand
BREAKER 1 OPEN
LED 10 operand
BREAKER 1 CLOSED
LED 11 operand
BREAKER 1 TROUBLE
LED 12 operand
Off
See the figure in the Setting Groups section of the Control Elements section later in this chapter for an example of group
activation.

5.3.10 User-programmable self tests

For user-programmable self-tests for CyberSentry, use the Setup > Security > Supervisory menu instead.
SETTINGS  PRODUCT SETUP  USER-PROGRAMMALBE SELF TESTS
 USER-PROGRAMMABLE
 SELF TESTS
All major self-test alarms are reported automatically with their corresponding FlexLogic operands, events, and targets.
Most of the minor alarms can be disabled if so wanted.
D30 LINE DISTANCE PROTECTION SYSTEM – INSTRUCTION MANUAL
Setting
LED 13 operand
LED 14 operand
LED 15 operand
LED 16 operand
LED 17 operand
LED 18 operand
LED 19 operand
LED 20 operand
LED 21 operand
LED 22 operand
LED 23 operand
LED 24 operand
DIRECT RING BREAK
FUNCTION: Enabled
DIRECT DEVICE OFF
FUNCTION: Enabled
REMOTE DEVICE OFF
FUNCTION: Enabled
FIRST ETHERNET FAIL
FUNCTION: Disabled
SEC. ETHERNET FAIL
FUNCTION: Disabled
THIRD ETHERNET FAIL
FUNCTION: Disabled
BATTERY FAIL
FUNCTION: Enabled
SNTP FAIL
FUNCTION: Enabled
IRIG-B FAIL
FUNCTION: Enabled
PTP FAIL
FUNCTION: Enabled
SFP MODULE FAIL
FUNCTION: Disabled
Parameter
Off
BREAKER 2 OPEN
BREAKER 2 CLOSED
BREAKER 2 TROUBLE
SYNC 1 SYNC OP
SYNC 2 SYNC OP
Off
Off
AR ENABLED
AR DISABLED
AR RIP
AR LO
Range: Disabled, Enabled. Valid for units equipped
with Direct Input/Output module.
Range: Disabled, Enabled. Valid for units equipped
with Direct Input/Output module.
Range: Disabled, Enabled
Range: Disabled, Enabled
Range: Disabled, Enabled
Range: Disabled, Enabled
Range: Disabled, Enabled
Range: Disabled, Enabled
Range: Disabled, Enabled
Range: Disabled, Enabled
Range: Disabled, Enabled
PRODUCT SETUP
5
5-93

Advertisement

Table of Contents
loading

Table of Contents