ORDER CODES
Table 2-7: D30 order codes for reduced-size vertical units with process bus
D30
- * **
BASE UNIT
D30
|
|
CPU
T |
U |
V |
SOFTWARE
00
03
A0
A3
B0
B3
2
C0
C3
D0
D3
E0
E3
F0
F3
G0
G3
J0
J3
K0
K3
L0
L3
MOUNT/COATING
FACEPLATE/ DISPLAY
POWER SUPPLY
PROCESS BUS MODULE
DIGITAL INPUTS/OUTPUTS
INTER-RELAY
COMMUNICATIONS
(select a maximum of 1 per unit)
For the last module, slot P is used for digital
input/output modules; slot R is used for inter-
relay
communications modules.
2-12
- * *
* - F **
- H **
- M **
- P/R **
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
V |
|
|
|
|
B |
|
|
|
|
F
|
|
|
|
D |
|
|
|
R |
|
|
|
A |
|
|
|
K |
|
|
|
M |
|
|
|
Q |
|
|
|
U |
|
|
|
L
|
|
|
|
N |
|
|
|
T
|
|
|
|
V |
|
|
|
W |
|
|
|
Y
|
|
|
|
I
|
|
|
|
J
|
|
|
|
H
|
|
|
L
|
|
|
|
81
|
XX
XX
Reduced Size Vertical Mount (see note regarding P/R slot below)
|
Base Unit
|
RS485 and Three Multi-mode fiber 100Base-FX (SFP with LC)
|
RS485 and Two Multi-mode fiber 100Base-FX (SFP with LC), One 10/100Base-TX
(SFP with RJ45)
|
RS485 and Three 10/100Base-TX (SFP with RJ45)
|
No Software Options
|
IEC 61850
|
CyberSentry Lvl 1
|
CyberSentry Lvl 1 and IEC 61850
|
IEEE 1588
|
IEEE 1588 and IEC 61850
|
Parallel Redundancy Protocol (PRP)
|
PRP and IEC 61850
|
IEEE 1588 and CyberSentry Lvl 1
|
IEEE 1588, CyberSentry Lvl 1, and IEC 61850
|
IEEE 1588 and PRP
|
IEEE 1588, PRP, and IEC 61850
|
PRP and CyberSentry Lvl 1
|
PRP, CyberSentry Lvl 1, and IEC 61850
|
IEEE 1588, PRP, and CyberSentry Lvl 1
|
IEEE 1588, PRP, CyberSentry Lvl 1, and IEC 61850
|
IEC 60870-5-103
|
IEC 60870-5-103 + IEC 61850
|
IEEE1588 + PRP + IEC 60870-5-103
|
IEEE1588 + PRP + IEC 60870-5-103 + IEC 61850
|
IEC 60870-5-103 + IEEE1588 + PRP + CyberSentry Lvl 1
|
IEC 60870-5-103 + IEEE1588 + PRP + CyberSentry Lvl 1 + IEC 61850
|
Vertical (3/4 rack)
|
Vertical (3/4 rack) with harsh environmental coating
|
English display
|
French display
|
Russian display
|
Chinese display
|
Enhanced front panel with English display
|
Enhanced front panel with French display
|
Enhanced front panel with Russian display
|
Enhanced front panel with Chinese display
|
Enhanced front panel with English display and user-programmable pushbuttons
|
Enhanced front panel with French display and user-programmable pushbuttons
|
Enhanced front panel with Russian display and user-programmable pushbuttons
|
Enhanced front panel with Chinese display and user-programmable pushbuttons
|
Enhanced front panel with Turkish display
|
Enhanced front panel with Turkish display and user-programmable pushbuttons
|
Enhanced front panel with German display
|
Enhanced front panel with German display and user-programmable pushbuttons
|
125 / 250 V AC/DC power supply
|
24 to 48 V (DC only) power supply
|
Standard 4CT/4VT
XX
No Module
4A
4 Solid-State (no monitoring) MOSFET outputs
4B
4 Solid-State (voltage with optional current) MOSFET outputs
4C
4 Solid-State (current with optional voltage) MOSFET outputs
4D
16 digital inputs with Auto-Burnishing (maximum of three modules within a case)
4L
14 Form-A (no monitoring) Latching outputs
67
8 Form-A (no monitoring) outputs
6A
2 Form-A (voltage with optional current) and 2 Form-C outputs, 8 digital inputs
6B
2 Form-A (voltage with optional current) and 4 Form-C outputs, 4 digital inputs
6C
8 Form-C outputs
6D
16 digital inputs
6E
4 Form-C outputs, 8 digital inputs
6F
8 Fast Form-C outputs
6G
4 Form-A (voltage with optional current) outputs, 8 digital inputs
6H
6 Form-A (voltage with optional current) outputs, 4 digital inputs
6K
4 Form-C and 4 Fast Form-C outputs
6L
2 Form-A (current with optional voltage) and 2 Form-C outputs, 8 digital inputs
6M 2 Form-A (current with optional voltage) and 4 Form-C outputs, 4 digital inputs
6N 4 Form-A (current with optional voltage) outputs, 8 digital inputs
6P
6 Form-A (current with optional voltage) outputs, 4 digital inputs
6R
2 Form-A (no monitoring) and 2 Form-C outputs, 8 digital inputs
6S
2 Form-A (no monitoring) and 4 Form-C outputs, 4 digital inputs
6T
4 Form-A (no monitoring) outputs, 8 digital inputs
6U
6 Form-A (no monitoring) outputs, 4 digital inputs
6V
2 Form-A outputs, 1 Form-C output, 2 Form-A (no monitoring) latching outputs, 8
digital inputs
2A
C37.94SM, 1300 nm single-mode, ELED, 1 channel single-mode
2B
C37.94SM, 1300 nm single-mode, ELED, 2 channel single-mode
2E
Bi-phase, single channel
2F
Bi-phase, dual channel
2G
IEEE C37.94, 820 nm, 128 kbps, multimode, LED, 1 Channel
2H
IEEE C37.94, 820 nm, 128 kbps, multimode, LED, 2 Channels
2I
Channel 1 - IEEE C37.94, MM, 64/128 kbps; Channel 2 - 1300 nm, single-mode,
Laser
2J
Channel 1 - IEEE C37.94, MM, 64/128 kbps; Channel 2 - 1550 nm, single-mode,
Laser
72
1550 nm, single-mode, Laser, 1 Channel
73
1550 nm, single-mode, Laser, 2 Channel
74
Channel 1 - RS422; Channel 2 - 1550 nm, single-mode, Laser
75
Channel 1 - G.703; Channel 2 - 1550 nm, single-mode Laser
76
IEEE C37.94, 820 nm, 64 kbps, multimode, LED, 1 Channel
77
IEEE C37.94, 820 nm, 64 kbps, multimode, LED, 2 Channels
7A
820 nm, multimode, LED, 1 Channel
7B
1300 nm, multimode, LED, 1 Channel
7C
1300 nm, single-mode, ELED, 1 Channel
7D
1300 nm, single-mode, Laser, 1 Channel
7E
Channel 1 - G.703; Channel 2 - 820 nm, multimode
7F
Channel 1 - G.703; Channel 2 - 1300 nm, multimode
7G
Channel 1 - G.703; Channel 2 - 1300 nm, single-mode ELED
7H
820 nm, multimode, LED, 2 Channels
7I
1300 nm, multimode, LED, 2 Channels
7J
1300 nm, single-mode, ELED, 2 Channels
7K
1300 nm, single-mode, Laser, 2 Channels