CHAPTER 4: INTERFACES
the minimum value. While at the minimum value, pressing the
continue downward from the maximum value.
FLASH MESSAGE
TIME: 2.5 s
NEW SETTING
HAS BEEN STORED
4.2.5.2 Entering enumeration data
Enumeration settings have data values that are part of a set, whose members are explicitly defined by a name. A set has
two or more members.
ACCESS LEVEL:
Restricted
Enumeration type values are changed using the
down arrow displays the previous selection.
VALUE
ACCESS LEVEL:
Setting
NEW SETTING
HAS BEEN STORED
4.2.5.3 Entering alphanumeric text
Text settings have data values that are fixed in length, but user-defined in characters. They can be upper-case letters,
lower-case letters, numerals, and a selection of special characters.
There are several places where text messages can be programmed to allow the relay to be customized for specific
applications. One example is the Message Scratchpad. Use the following procedure to enter alphanumeric text messages.
For example, enter the text "Breaker #1".
1.
Press the decimal point to enter text edit mode.
2.
Press the
keys until the character 'B' appears; press the decimal key to advance the cursor to the next position.
VALUE
3.
Repeat step 2 for the remaining characters: r,e,a,k,e,r, ,#,1.
4.
Press
to store the text.
ENTER
5.
If you have any problem, press
seconds each. For the case of a text setting message, pressing

4.2.6 Faceplate

4.2.6.1 Enhanced faceplate
The front panel consists of LED panels, an RS232 port, keypad, LCD display, control pushbuttons, and optional user-
programmable pushbuttons.
The faceplate is hinged to allow access to the removable modules.
D30 LINE DISTANCE PROTECTION SYSTEM – INSTRUCTION MANUAL
As an example, set the flash message time setting to 2.5 seconds. Press the appropriate numeric
keys in the sequence "2 . 5". The display message changes as the digits are being entered.
Until ENTER is pressed, editing changes are not registered by the relay. Press ENTER to store the
new value in memory. This flash message momentarily appears as confirmation of the storing
process. Numerical values that contain decimal places are rounded-off if more decimal place digits
are entered than specified by the step value.
For example, the selections available for ACCESS LEVEL are "Restricted," "Command," "Setting," and
"Factory Service."
keys. The
VALUE
If the ACCESS LEVEL needs to be "Setting," press the VALUE keys until the proper selection displays.
Press HELP at any time for the context sensitive help messages.
Changes are not registered by the relay until the ENTER key is pressed. Pressing ENTER stores the
new value in memory. This flash message momentarily appears as confirmation.
to view context sensitive help. Flash messages appear sequentially for several
HELP
down arrow again allows the setting selection to
VALUE
up arrow displays the next selection while the
VALUE
displays how to edit and store new values.
HELP
FRONT PANEL INTERFACE
4-15