Service Menus - Woodward 723PLUS Technical Manual

Two-engine redundant lon torque sharing marine propulsion application
Table of Contents

Advertisement

723PLUS Digital Marine Control
Manual 26482
04 SHUTDOWN WHEN PID@0 (*T/F)—Set this value "FALSE" if no action is to
be taken when the PID @ ZERO alarm occurs. Set this value "TRUE", and a PID
@ ZERO alarm will cause an Emergency Declutch.
05 PID @ ZERO LEVEL (*0.0–100.0)—The units for this value are percent of the
actuator output driver. Set this value for the desired level that the PID output
must be below before an alarm will occur.
06 PID @ ZERO TIME (*0.0–120.0)—The units for this value are seconds. Set
this value for the duration that the PID output must be below the value set at
prompt PID @ ZERO LEVEL before an alarm will occur.
07 HIGH ACT ALM LEVEL (%) (0.0–100.0)—The units for this value are percent
of the actuator driver output. Set this value for the desired level that the PID
output must be above before the HIGH ACT ALARM is tripped.
08 OVERSPEED SD (1–2200 rpm)—The units for this value are rpm. Set this
value to the desired high speed shutdown point.
09 LON ALM DELAY TIME (*SEC)—Set the delay time to wait before latching
the CLON CH1 ERROR, CLON CH2 ERROR and PORT 3 LINK ERROR into a
minor or major alarm state.
10 ACTUATOR MODE SWITCH DELAY (*SEC)—Set the delay time to wait
before latching the ACTUATOR MODE SWITCH DELAY discrete input into a
minor or major alarm state.
F**CFIG COM PORT 2**
The 723PLUS has two serial ports. Port 2 and Port 3 are configured as Servlink
ports.
01 PORT 2 ADDRESS determines the port's multidrop Servlink network address.
Set between 0 and 15.

Service Menus

A**DISPLAY 1**
01 ENGINE SPEED (RPM)—This is the sensed engine speed.
02 SPEED REFERENCE (RPM)—This is the present value of the engine speed
reference.
03 ACTUATOR COMMAND %—This is the actuator output command
percentage to the actuator. This value is the output of the final driver and may be
forward (direct) or reverse (indirect) acting. The percentage is proportional to the
actuator current (0–200 mA).
04 ACTUATOR COMMAND (mA)—This the actuator output command to the
actuator in milliamps (0–200 mA)
05 TORQUE INPUT (4–20 mA)—This is the torque sensor 4–20 mA input
(Analog Input #1) signal value, displayed in milliamps.
50