723PLUS Control Specifications

Low Voltage Model
Power Consumption
Inrush Current
Speed Signal Inputs (2)
Speed Input Voltage
Speed Input Frequency
Speed Input Impedance
Note: EU Directive compliant applications are not currently able to use proximity switches due to the sensitivity of the
Discrete Inputs (8)
Discrete Input
Response Time
Impedance
Note: For Lloyd's Register applications, use only control-supplied power.
Analog Inputs (4)
Analog Input
Common Mode Voltage
Common Mode Rejection
Torque Sharing Input
Analog Input
Common Mode Voltage
Common Mode Rejection
Analog Outputs 0–1 or 4–20 mA (2)
Analog Output
Analog Outputs 0–20 or 0–200 mA (2)
Analog Output
Relay Contact Outputs (3)
Contact Ratings
Operating Temperature
Storage Temperature
Mechanical Vibration
Mechanical Shock
EMI/RFI Specification
UL/cUL Listing
Marine Listings
European Union (EU)
Input Power
18–40 Vdc (24 or 32 Vdc nominal)
40 W nominal
7 A for 0.1 ms
Inputs
1.0–50.0 Vrms
Magnetic Pickup: 400 Hz to 15 kHz; Proximity Switch: 30 Hz to 15 kHz
10 k ± 15%
switches.
24 Vdc, 10 mA nominal, 18–40 Vdc range
10 ms ±15%
2.3 k
±5 Vdc or 0–20 mA, transducers externally powered
±40 Vdc
0.5% of full scale
Accuracy
0.5% of full scale
0–4.5 Vdc
±40 Vdc
1.0% of full scale
Accuracy
1.0% of full scale
Outputs
0–1 mA or 4–20 mA (max. 600  load)
Accuracy
0.5% of full scale
0–20 mA (max. 600  load) or 0–200 mA (max. 70  load)
Accuracy
0.5% of full scale
2.0 A resistive @ 28 Vdc; 0.5 A resistive @ 125 Vdc
Environment
–40 to +70 °C (–40 to +158 °F)
–55 to +105 °C (–67 to +221 °F)
Humidity
95% at +20 to +55 °C (+68 to +131 °F)
Lloyd's Register of Shipping Specification Humidity Test 1
Lloyd's Register of Shipping Specification Vibration Test 1
US MIL-STD 801C Method 516.2, Proc. I, II, V
Lloyd's Register of Shipping Specification
EN 50081–2 and EN 50082–2
Compliance
Class I, Division 2, Groups A, B, C, & D
Lloyd's Register of Shipping (LR), Germanischer Lloyd (GL), American
Bureau of Shipping (ABS, Low Voltage Models only), Bureau Veritas (BV),
Det Norske Veritas (DNV), Nippon Kaiji Kyokai (NKK), Registro Italiano
Navale (RINA)
Compliant with EMC Directive 2004/108/EC and Low Voltage Directive
2006/95/EC.