Woodward 723PLUS Technical Manual page 52

Two-engine redundant lon torque sharing marine propulsion application
Table of Contents

Advertisement

723PLUS Digital Marine Control
To enter the I/O Lock mode and enable a configure value to be entered,
click on the I/O Lock icon on the Tool Bar. Because the values set in Configure
are critical to engine operation, it is not safe to operate the prime mover while
these parameters are being configured. In the Configure mode the control
outputs will be set to their off state, and the microprocessor will stop executing
the application code. The control will have to be Reset to continue operation.
The Reset icon allows the microprocessor to store the configure
parameters, to return the outputs to their active state, and to resume executing
the application software.
When the tuning or setting of parameters is complete, the values must be
saved in the control's non-volatile memory. Go to the Tool Bar and click the
PROM icon for Save Values. The values will be saved in non-volatile memory
and will be unaffected by loss of power to the control.
If an application configuration has been previously saved to a *.CFG file,
the saved set of parameters can be loaded into the 723PLUS as a group by
selecting the Load Application Settings icon.
To save the configuration to a file in the external computer for backup or
download later into another 723PLUS when a similar system is being set up,
select the Save Application Settings icon. All the tunable values presently set in
the control will be saved to a file and can be loaded into this 723PLUS, control to
reprogram it to the saved values or into another 723PLUS, at a later time.
42
Manual 26482
Woodward