Woodward 723PLUS Technical Manual page 48

Two-engine redundant lon torque sharing marine propulsion application
Table of Contents

Advertisement

723PLUS Digital Marine Control
Manual 26482
An "inspector" provides a window for real-time monitoring and editing of all
control Configuration and Service Menu parameters and values. Custom
"inspectors" can easily be created and saved. Each window can display up to 28
lines of monitoring and tuning parameters without scrolling. The number with
scrolling is unlimited. Two windows can be open simultaneously to display up to
56 parameters without scrolling. Tunable values can be adjusted at the inspector
window. Watch Window communicates with the control through an RS-232 cable
connection to the communication port which is configured as a point-to-point only
Servlink Server.
The 723PLUS's default baud rate is 19200, which needs to be entered in the
Servlink Network Options window. Servlink will be initialized correctly for all other
port parameters except BAUD rate.
Check the 'pull-down' menu CONTROL \ PROPERTIES to display the part
number and revision level of the software in the control. Refer to this number and
revision level in any correspondence with Woodward (write this information in the
programming checklist, Appendix D). The Watch Window software has extensive
help assistance through the Help Menu.
Follow these steps to communicate with the control:
Step 1:
Open a Servlink Window. Go to Start \ Programs \ Woodward \ Servlink Server \
Servlink Server, and click on the Servlink Server to start the software.
38