Hot Swap Led Control Register - Kontron CP6500-V User Manual

Table of Contents

Advertisement

CP6500-V
4.5.13

Hot Swap LED Control Register

The hot swap LED control register enables the user to switch on and off the hot swap LED on
the front panel.
Table 4-27: Hot Swap LED Control Register
REGISTER NAME
ADDRESS
BIT POSITION
CONTENT
DEFAULT
BIT
NAME
0
1
2
HSLED
3
4
5
6
7
ID 28945, Rev. 01
Hot Swap LED Control Register
7
6
5
Res.
Res.
Res.
0
0
0
VAL
0
Reserved
0
Reserved
0
Hot swap LED switch off
1
Hot swap LED switch on
0
Reserved
0
Reserved
0
Reserved
0
Reserved
0
Reserved
© 2005 Kontron Modular Computers GmbH
0x28E
4
3
Res.
Res.
0
0
DESCRIPTION
Configuration
ACCESS
R
W
2
1
0
HSLED
Res.
Res.
0
0
0
Page 4 - 19