Ericsson RX8000 Reference Manual page 91

Integrated receivers/decoders
Hide thumbs Also See for RX8000:
Table of Contents

Advertisement

EN/LZT 790 0005 R7A
SNTP Sync Error (relay mapping) – Place a check mark in the box to activate
relay mapping for SNTP sync error.
DownConverter FW Error – Select the alarm condition from the drop-down
menu to be activated when the high quality down-converter FPGA interface
presents an error (Set Alarm /No Alarm).
DownConverter FW Error (relay mapping) – Place a check mark in the box to
activate relay mapping for down-converter firmware error.
Unsupported Video Format - Select the alarm condition from the drop-down
menu to be activated when the high quality down-conversion card detects an
unsupported video format (Set Alarm /No Alarm).
Unsupported Video Format (relay mapping) – Place a check mark in the box
to activate relay mapping for unsupported video format.
Filter Output Overflow – Select the alarm condition from the drop-down menu
to be activated when the multi service filter block detects an overflow within its
buffers (Set Alarm /No Alarm).
Filter Output Overflow (relay mapping) – Place a check mark in the box to
activate relay mapping for filter output overflow.
No CSMs received – Select the alarm condition from the drop-down menu to be
activated when the unit in a redundant nCC system receives no CSM
redundancy control packets (Set Alarm /No Alarm).
No CSMs received (relay mapping) – Place a check mark in the box to
activate relay mapping for no CSMs received.
Subtitles Failed - Select the alarm condition from the drop-down menu to be
activated when DVB or Teletext subtitles fails (Set Alarm /No Alarm).
Subtitles Failed (relay mapping) – Place a check mark in the box to activate
relay mapping for subtitle fails.
TS not locked on 422 card – Select the alarm condition from the drop-down
menu to be activated when there is an issue with the Transport Stream input to
the 4:2:2 Decoder Option card.
TS not locked on 422 card (relay mapping) – Place a check mark in the box to
activate relay mapping for TS not locked on 422 card error.
Decoder not ready on 422 card – Select the alarm condition from the drop-
down menu to be activated when the video decoder on the 4:2:2 Decoder
Option card is not ready to operate.
Decoder not ready on 422 card (relay mapping) – Place a check mark in the
box to activate relay mapping for Decoder not ready on 422 card error.
Decoder error on 422 card – Select the alarm condition from the drop-down
menu to be activated when the video decoder on the 4:2:2 Decoder Option card
is in an error state.
Using the Equipment
3-51

Advertisement

Table of Contents
loading

Table of Contents