SAT S2X Upgrade Failed (relay mapping) – Place a check mark in the box to
activate relay mapping when this alarm is raised.
SAT S2X Not Calibrated – Select the alarm condition from the drop-down menu
to be activated if this alarm is raised. This alarm is raised if there is a calibration
error on the DVB-S2X card.
SAT S2X Not Calibrated (relay mapping) – Place a check mark in the box to
activate relay mapping when this alarm is raised.
SAT S2X Undefined Internal Error – Select the alarm condition from the drop-
down menu to be activated if this alarm is raised. This alarm is raised when
there an internal error reported by the DVB-S2X card.
SAT S2X Undefined Internal Error (relay mapping) – Place a check mark in
the box to activate relay mapping when this alarm is raised.
SAT S2X Input Level Too High – Select the alarm condition from the drop-
down menu to be activated if this alarm is raised. This alarm is raised when the
DVB-S2X card experiences an input level that is too high.
SAT S2X Input Level Too High (relay mapping) – Place a check mark in the
box to activate relay mapping when this alarm is raised.
SAT S2X Failed To Acquire PLL – Select the alarm condition from the drop-
down menu to be activated if this alarm is raised. This alarm is raised when
DVB-S2X card fails to acquire Physical Layer lock (not applicable for DVB-S).
SAT S2X Failed To Acquire PLL (relay mapping) – Place a check mark in the
box to activate relay mapping when this alarm is raised.
SAT S2X Failed To Acquire Lock – Select the alarm condition from the drop-
down menu to be activated if this alarm is raised. This alarm is raised when
DVB-S2X card fails to acquire lock
SAT S2X Failed To Acquire Lock (relay mapping) – Place a check mark in
the box to activate relay mapping when this alarm is raised.
SAT S2X DC Overcurrent – Select the alarm condition from the drop-down
menu to be activated if this alarm is raised. This alarm is raised when a DC
overcurrent is detected on the input of the DVB-S2X card.
SAT S2X DC Overcurrent (relay mapping) – Place a check mark in the box to
activate relay mapping when this alarm is raised.
SAT S2X Core Overloaded – Select the alarm condition from the drop-down
menu to be activated if this alarm is raised. This alarm is raised when the DVB-
S2X card decoder core is too high loaded.
SAT S2X Core Overloaded (relay mapping) – Place a check mark in the box
to activate relay mapping when this alarm is raised.
SAT S2X Buffer Overflow – Select the alarm condition from the drop-down
menu to be activated if this alarm is raised. This alarm is raised when a buffer
mismatch occurs in the DVB-S2X card.
EN/LZT 790 0005 R7A