Using the Equipment
3-44
C/N Margin (min value) – Enter the Carrier-to-Noise margin minimum value in
decibels. This is used to trigger the alarm condition, set above, when exceeded.
C/N Margin (relay mapping) – Place a check mark in the box to activate relay
mapping for C/N Margin exceeded alarm.
SNR (min value)
Enter the Signal to Noise Ratio minimum value in decibels.
This is used to trigger the alarm condition, set above, when exceeded
SNR (relay mapping) – Place a check mark in the box to activate relay mapping
for SNR exceeded alarm
IPI Ethernet IF 1 and 2 Down – Select the alarm condition from the drop-down
menu to be activated when both Ethernet inputs lose network connectivity (Set
Alarm /No Alarm).
IPI Ethernet IF 1 and 2 Down (relay mapping) – Place a check mark in the box
to activate relay mapping for Ethernet 1 and 2 down.
IPI Ethernet If 1 and 2 No Data
down menu to be activated when both Ethernet Transport Stream inputs loose
Transport Stream lock (Set Alarm /No Alarm).
IPI Ethernet If 1 and 2 No Data (relay mapping) – Place a check mark in the
box to activate relay mapping for Ethernet input 1 and 2 loss of Transport
Stream alarm.
IPI Ethernet If 1 Down – Select the alarm condition from the drop-down menu
to be activated when Ethernet input port 1 loses network connectivity (Set Alarm
/No Alarm).
IPI Ethernet If 1 Down (relay mapping) – Place a check mark in the box to
activate relay mapping for IPI Ethernet If 1 Down alarm.
IPI Ethernet If 1 No Data – Select the alarm condition from the drop-down menu
to be activated when Ethernet input port 1 loses Transport Stream data lock (Set
Alarm / No Alarm).
IPI Ethernet If 1 No Data (relay mapping) – Place a check mark in the box to
activate relay mapping IPI Ethernet IF 1 No Data alarm.
IPI Ethernet If 1 IP Conflict – Select the alarm condition from the drop-down
menu to be activated when Ethernet input port 1 senses a conflict of IP address
with another device (Set Alarm / No Alarm).
IPI Ethernet If 1 IP Conflict (relay mapping) – Place a check mark in the box
to activate relay mapping for IPI Ethernet If 1 IP Conflict alarm.
IPI Ethernet If 2 Down – Select the alarm condition from the drop-down menu
to be activated when Ethernet input port 2 loses network connectivity (Set Alarm
/No Alarm).
IPI Ethernet If 2 Down (relay mapping) – Place a check mark in the box to
activate relay mapping for Transport Stream loss of lock alarm.
Select the alarm condition from the drop-
EN/LZT 790 0005 R7A