IPI Ethernet If 2 No Data – Select the alarm condition from the drop-down menu
to be activated when Ethernet input port 2 loses Transport Stream data lock (Set
Alarm / No Alarm).
IPI Ethernet If 2 No Data (relay mapping) – Place a check mark in the box to
activate relay mapping for IPI Ethernet If 2 No Data alarm.
IPI Ethernet If 2 IP Conflict – Select the alarm condition from the drop-down
menu to be activated when Ethernet input port 2 senses a conflict of IP address
with another device (Set Alarm / No Alarm).
IPI Ethernet If 2 IP Conflict (relay mapping) – Place a check mark in the box
to activate relay mapping for IPI Ethernet If 2 IP Conflict alarm.
Out of sync – Select the alarm condition from the drop-down menu to be
activated when the Transport Stream de-encapsulation from IP loses sync with
the transport packets (Set Alarm / No Alarm).
Out of sync (relay mapping) – Place a check mark in the box to activate relay
mapping for out of sync alarm.
No Response – Select the alarm condition from the drop-down menu to be
activated when the motherboard loses response form the IP input card (Set
Alarm / No Alarm).
No Response (relay mapping) – Place a check mark in the box to activate
relay mapping for no response alarm.
Wrong FEC format – Select the alarm condition from the drop-down menu to be
activated when the IP card detects that the incoming IP datagrams have the
wrong FEC for the current configuration (Set Alarm / No Alarm).
Wrong FEC format (relay mapping) – Place a check mark in the box to
activate relay mapping for wrong FEC format alarm.
FIFO overflow – Select the alarm condition from the drop-down menu to be
activated when the IP card 's input FIFO overflows (Set Alarm / No Alarm).
FIFO overflow (relay mapping) – Place a check mark in the box to activate
relay mapping for input FIFO overflow alarm.
Primary interface not in use – Select the alarm condition from the drop-down
menu to be activated when due to redundancy switching the primary IP interface
port is no longer being used (Set Alarm / No Alarm).
Primary interface not in use (relay mapping) – Place a check mark in the box
to activate relay mapping for the primary interface not in use alarm.
Primary TS not in use – Select the alarm condition from the drop-down menu
to be activated when due to redundancy switching the IP inputs primary data
connection (multicast address) is no longer being used (Set Alarm / No Alarm).
Primary TS not in use (relay mapping) – Place a check mark in the box to
activate relay mapping for primary TS not in use alarm.
Using the Equipment
3-45