Subtitle And Caption Alarm Identifiers; Ip Output Alarm Identifiers; Service Split Alarm Identifiers - Ericsson RX8000 Reference Manual

Integrated receivers/decoders
Hide thumbs Also See for RX8000:
Table of Contents

Advertisement

Name
FAN 3 Failed
FAN 4 Failed
C.2.6

Subtitle and Caption Alarm Identifiers

Table C.6 Closed Caption Alarm Identifiers
Name
Closed Caption Fail
Subtitles Failed
C.2.7

IP Output Alarm Identifiers

Table C.7 IP Output Alarm Identifiers
Name
IPO Ethernet If 1 Down
IPO Ethernet If 2 Down
IPO Ethernet IF 1 & 2 Down
IPO MGP Error
IPO MGP Duplicate
No CSMs received
C.2.8

Service Split Alarm Identifiers

Table C.8 Service Split Alarm Identifiers
Name
Filter Output Overflow
Service Split Overrate
EN/LZT 790 0005 R7A
Identifier
Description
1033
FAN 3 Failure
1034
FAN 4 Failure
Identifier
Description
1040
Closed captions output failure
1041
DVB or Teletext Subtitle renderer is
Out Of Memory
or
Scaling DVB or Teletext Subtitles are
too big to fit in to the display safe area
Identifier
Description
1050
Link down on IP output port 1
1051
Link down on IP output port 2
1052
Both links down
1053
MGP protocol error
1054
Potential duplicate stream detected
1055
Not receiving redundancy CSM
messages on control port
Identifier
Description
1060
Service filter output bit rate is not high
enough for the data rate. Packet drop
detected.
1061
Service output bit rate is not high
enough for the data rate.