SC800: Overall System
Could not initialize or read the bus connection.
[50B1]
SSCG register value was incorrect.
[50B2]
SC834
D Self-diagnostic error: optional memory
An error occurred after write/verify check for optional RAM on the
motherboard..
[5101]
SC838
D
Self-diagnostic error: Clock generator
A verify error occurred when setting data was read from the clock
generator via the I2C bus
[2701]
D131/D132/D133
Defective connection bus
Defective SSCG
Replace the motherboard (engine I/F board).
Defective connection bus
Defective SSCG
Replace the motherboard (engine I/F board).
Defective memory device
Replace the motherboard (engine I/F board).
Defective clock generator
Defective I2C bus
Defective I2C port on the CPU
Replace the controller board.