5. SYSTEM MAINTENANCE

5.1 RESETS

5.1.1 MEMORY ALL CLEAR: SP5801

Before shipping, the SP mode data settings are printed in an SMC Report and attached to the
exposure glass of the machine for your reference. Store this report in a safe place (next to the
toner collection bottle, for example). It is a list of all the SP initial settings. Refer to this list if you
need to initialize one or more SPs. The initial SP settings are also written in the SP mode tables at
the end of this section.
As a rule, you should always print an SMC Report before initializing or adjusting the SP settings.
The SMC Report provides a concise list of all the SP commands and their current settings. The
report can be used for reference if the service manual is not available.
Executing Memory All Clear resets all the settings stored in the NVRAM to their default settings
except the following:
SP5811-001
Machine serial number
SP5907
Plug & Play Brand Name and Production Name Setting
1.
Execute SP5990 to print out all SMC Data Lists.
2.
Open SP mode 5801.
3.
Press the number for the item that you want to initialize. The number you select determines
which application is initialized. For example, press 1 if you want to initialize all modules.
Memory Clear
5801
Resets NVRAM data to the default settings. Before executing any of these SP
codes, print an SMC Report.
001
All Clear
002
Engine Clear
003
SCS
SM
Initializes items 2 to 15 below.
Initializes all registration settings for the engine and
copy process settings.
Initializes default system settings, SCS (System Control
Service) settings, operation display coordinates, and
ROM update information.