Additional Sc Codes Printed In Smc Report - Ricoh D131 Service Manual

Table of Contents

Advertisement

SC900: Miscellaneous
Note 1
If a problem always occurs in a specific condition (for example. printer driver setting, image file),
the problem may be caused by a software error. In such a case, the following data and information
need to be sent back to your product specialist. Please understand that it may take some time to
get a reply on how to solve the problem, because in some cases the design staff in Japan must
analyze the data.
Symptom / Possible Causes / Action taken
Summary sheet (SP mode "Printer SP", SP1-004 [Print Summary])
SMC - All (SP5-990-001)
SMC - Logging (SP5-990-004)
Printer driver settings used when the problem occurs
All data displayed on the screen (SC code, error code, and program address where the
problem is logged.)
Image file which causes the problem, if possible

2.10.2 ADDITIONAL SC CODES PRINTED IN SMC REPORT

These codes are also used in the SMC report. Codes that have the same number in this series
are identified by an additional 4-digit hexadecimal number.
TLB conversion (store) exception
820
0001
error
820
0002
TLB miss (load) exception error
820
0003
TLB miss (store) exception error
820
0004
Read address exception error
820
0005
Write address exception error
820
0006
Command bus exception error
820
0007
Data bus exception error
820
0008
System call exception error
820
0009
Break exception error
820
000A
Illegal command exception error
820
000B
Potential sensor exception error
820
000C
Overflow exception error
D131/D132/D133
Unexpected error in CPU
device:
Controller board defective
Boot monitor or
self-diagnostic program
corrupted
2-100