Development Unit
Reinstallation
1.
Hold the hopper perfectly level when re-attaching it, to prevent toner from entering the rails of
the development filter.
Automatic process control starts automatically after the machine is switched on, so
after replacing the developer, you should enter the SP mode and initialize the
developer with SP2801 as soon as possible after switching the machine on.
2.
Do SP2801 (TD Sensor Initial Setting).
Open the front door.
Turn the machine on
If you open the front door, auto process control will not start. SP2801 must be done
before auto process control starts.
Push [Clear Modes]
Enter the SP mode.
Close the front door.
Push "System SP" on the touch-panel.
Enter 2801-002 to select SP2801-002.
On the soft keys, enter the lot number from the pack of developer, then push [#].
Do SP2801-1.
D131/D132/D133
4-56
SM